| Supply Voltage | 105 to 130V ac (60 Hz) |
|---|---|
| Output Power | 120 mA max.: 12V dc min., 30V dc max. (dependent on load) |
| Output Configuration | SPS101Q(P) models:SPST electromechanical relay (Form A) SPS101SQ(P) models:Optically isolated SPST solid-state switch |
| Output Rating | SPS101Q(P) models: Max. switching power (resistive load):150W, 600VA
Max. switching voltage (resistive load):250V ac or 30V dc (120V ac max. per UL & CSA)
Max. switching current (resistive load):5 A
Min. voltage and current:1 A @ 5V dc; 0.1 A @ 24V dc
Peak switching voltage:750V ac (transient suppression recommended)
Mechanical life of relay:10,000,000 operations
SPS101SQ(P) models:Max. switching voltage:250V ac or dc
Max. switching current:300 mA
ON-state saturation voltage:less than 3V @ 300 mA; less than 2V @ 15 mA
OFF-state leakage current:less than 50 µA
Inrush current: 1 A for 20 milliseconds, non-repetitive
Note:Output of the solid-state models is not short-circuit protected. Exercise care when making wiring connections. |
| Status Indicators | 2 LED Indicators:Green and Red Green ON steady:power ON
Red ON steady:output ON
|
| Connections | Power connector:5-pin Mini-style quick-disconnect fitting. QD cables are ordered separately. Sensor connector: Q suffix:5-pin Euro-style quick-disconnect fitting
QP suffix:0.5 m shielded pigtail with 5-pin Euro-style quick-disconnect fitting
|
| Environmental Rating | IEC IP54 |
| Operating Conditions | Temperature:-20° to +50° C Relative humidity:90% @ 50° C (non-condensing) |
| Additional Notes | Compatible with Banner dc sensors with NPN or PNP output with a 4- or 5-pin Euro-style quick-disconnect (except NAMUR sensors). Minimum of 630V isolation from earth ground to dc output of circuit. |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Banner has more than 2,000 distributors worldwide - ready to help you. Enter a U.S. zip code