| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ 40 mA max. (exclusive of load) |
|---|---|
| Range | 200 mm to 8 m |
| Ultrasonic Frequency | 75 kHz
Rep. rate:96 milliseconds |
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
| Output Configuration | Voltage sourcing:0-10V dc Current sourcing:4-20 mA |
| Output Rating | 0-10V dc models: Minimum load resistance:500 ohms
Minimum required supply voltage for full 0-10V output span:[(1000/RLOAD)+13]V dc
4-20 mA models:Maximum load resistance:1 k ohms or [(V supply/0.02) - 5] ohms, whichever is lower
Minimum required supply voltage for full 4-20 mA output span:10V dc or [(RLOAD x 0.02) + 5]V dc, 4-20 mA output calibrated at 25° C with a 250 ohms load.
|
| Output Protection | Protected against short circuit conditions |
| Output Response Time | 100 to 2300 milliseconds |
| Delay at Power-up | 1.5 seconds |
| Temperature Effect | Uncompensated:0.2% of distance/° C Compensated:0.02% of distance/° C |
| Linnearity | +/- 0.2% of span from 200 to 8000 mm; +/- 0.1% of span from 500 to 8000 mm (1 mm minimum) |
| Repeatability | 1.0 mm |
| Minimum Window Size | 20 mm |
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons or remotely using TEACH input. |
| Indicators | Green Power ON LED:indicates power is ON Red Signal LED:indicates target is within sensing range, and the condition of the received signal TEACH/Output indicator (bicolor Yellow/Red): Yellow:target is within taught limits
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
|
| Remote TEACH | To TEACH:connect gray or yellow wire to 0 to +2V dc; impedance 12 k ohms |
| Construction | Transducer:ceramic/epoxy composite Housing:ABS/Polycarbonate Membrane switch:polyester Lightpipes:acrylic |
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P |
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro- or Mini-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-20° to +70° C Relative humidity:100% |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Temperature Warmup Drift | Less than 0.8% of sensing distance upon power-up with Temperature Compensation enabled |
| Application Note | Objects passing inside the specified near limit (200 mm) may produce a false response. |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | U-GAGE QT50U Series, Analog Output (dc models) |
70137 | 824K | Download Email |
| 2. | U-GAGE QT50U Series, Mounting Flange (SAFQT50U) |
116804 | 455K | Download Email |
| 3. | U-GAGE QT50U, T30U Series, Teflon Flange | 122155 | 420K | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | Ultrasonic Sensing Flyer - Greek | A100_Ultrasonic_6page_Greek | 3MB | Download Email |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Is your line competitive? Innovative, high-quality solutions for every phase of production. Enjoy increased accuracy, greater productivity, cost savings.
Learn more »Banner has more than 2,000 distributors worldwide - ready to help you. Enter a U.S. zip code