| Safety and Non-Safety Inputs (22 terminals) | Input ON threshold:greater than 15V dc (guaranteed on), 30V dc max.
Input OFF threshold:less than 5V dc (guaranteed off with any 1 fault), –3V dc min.
Input ON current:8 mA typical @ 24V dc, greater 2 mA (guaranteed with 1 fault); 50 mA peak contact cleaning current @ 24V dc
Sourcing current:30 mA minimum continuous (3V dc max. drop)
Input lead resistance:300 ohms max. (150 ohms per lead)
|
| Power | 24V dc, ± 20%
0.4 A (controller only), 5.9 A (all outputs ON @ full rated load)
The Controller should be connected only to a SELV or PELV power supply.
|
| Safety Outputs (6 terminals, 3 redundant outputs) | Rated output current:0.75 A max. @ 24V dc (1.0V dc max. drop)
Output OFF threshold:0.9V dc typical (1.2V dc max. guaranteed with 1 fault)
Output leakage current:50 μA max. with open 0V
Load:0.1 μF max., 1 H max., 10 ohms max. per lead
|
| Status Outputs (10 terminals) | Rated output current:0.5A @ 24V dc (individual), 1.0 A @ 24V dc (total of all outputs)
O1 to O8 (General Purpose) Output OFF voltage:less than 0.5V dc (no load)
O9 and O10 (Monitored Mute Lamp) Output OFF voltage:internal 94 kohms pull up to V supply
O9 and O10 (Monitored Mute Lamp) Output ON/OFF threshold:15V dc +/-4V dc @ 24V dc supply
Note:For O9 and O10, if a short circuit or other fault condition causes the output to drop below this threshold while the output is ON, a lockout will occur. If an open circuit or other fault condition causes the output to rise above this threshold while the output is OFF, a lockout will occur.
|
| Response and Reaction Times | Response time (ON to OFF):10 milliseconds max. (with standard 6 milliseconds debounce; this can increase if debounce time increases. Refer to the configuration summary for actual response time.)
Reaction time (OFF to ON):400 milliseconds max. (with manual reset option)
Reaction time (OFF to ON):400 milliseconds max. plus input debounce time (auto reset)
|
| Onboard LCD Information Display—Password Requirements | Password is not required:
Run mode (I/O status)
Fault (I/O fault detection and remedial steps)
Review configuration parameters (I/O properties and terminals)
Password is required:
Configuration mode (create/modify/confirm/download configurations)
|
| Environmental Rating | NEMA 1 (IEC IP20), for use inside NEMA 3 (IEC IP54) or better enclosure
|
| Operating Conditions | Temperature range:0° to +55° C
|
| Mechanical Stress | Shock:15 g for 11 milliseconds, half sine, 18 shocks total (per IEC 61131-2)
Bump:10 g for 16 milliseconds, 6000 cycles total (per IEC 61496-1)
Vibration:3.5 mm occasional / 1.75 mm continuous @ 5Hz to 9 Hz, 1.0 g occasional and 0.5 g continuous @ 9 to 150 Hz: (per IEC 61131-2) and 0.35 mm single amplitude / 0.70 mm peak-to-peak @ 10 to 55 Hz (per IEC 61496-1), all @ 10 sweep cycles per axis
|
| EMC | Meets or exceeds all EMC requirements in IEC 61131-2, IEC 61496-1 (Type 4), and IEC 62061 Annex E, Table E.1 (increased immunity levels)
|
| Removable Terminals | Screw terminals:
Wire sizes:16, 18, 20, 22 or 24 AWG (0.20 – 1.31 mm2)
Wire strip length:5.00 mm
Tightening torque:0.23 Nm (2 in. lbs) nominal
Tightening torque:0.34 Nm (3.0 in. lbs) maximum
Clamp terminals:
Wire size:16, 18, 20, 22, or 24 AWG (0.20 – 1.31 mm2)
Wire strip length:9.00 mm
Important:The clamp terminals are designed for 1 wire only. If more than 1 wire is connected to a terminal, a wire could loosen or become completely disconnected from the terminal, causing a short.
|
| Product Performance Standards | *SIL 3 per IEC 62061 Safety of Machinery – Functional Safety of Safety-Related Electrical, Electronic and Programmable Electronic Control Systems.
*SIL 3 per IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems
*Category 4 per ISO 13849-1 (EN954-1) Safety of Machinery. Safety Related Parts of Control Systems
*Performance Level (PL) e per ISO 13849-1
*IEC 61131-2 Programmable Controllers, Part 2: Equipment Requirements and Tests
*UL 508 Industrial Control Equipment
*UL 1998 Software in Programmable Components
*ANSI NFPA 79 Electrical Standards for Industrial Machinery
*IEC 60204-1 Electrical Equipment of Machines: General Requirements
*EN 954-1 Safety of Machinery. Safety Related Parts of Control Systems. General Principles.
*ISO 13851 (EN574) Safety of Machinery – Two-Hand Control Devices – Functional Aspects and Design Principles
*ISO 13850 (EN418) Emergency Stop Devices
|