| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ less than 25 mA (exclusive of load)
|
| Range | Varies by sensing mode and fiber optics used
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltage
|
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing)
|
| Output Rating | 100 mA max. output with short-circuit protection
OFF-state leakage current:less than 10 µA sourcing; 200 µA sinking
ON-state saturation voltage:
NPN:1.6V @ 100 mA
PNP:2.0V @ 100 mA
|
| Output Protection Circuitry | Protected against output short-circuit and false pulse on power up
|
| Output Response Time | Standard models:500 microseconds (with crosstalk avoidance circuitry)
High-speed models:200 microseconds
|
| Delay at Power-up | 100 millisecond; outputs do not conduct during this time.
|
| Repeatability | Standard models:95 microseconds
High-speed models:50 microseconds
|
| Adjustments | 12-turn Sensitivity potentiometer with relative position indicator; light operate (LO)/dark operate selection switch; 0 or 40 milliseconds OFF-delay switch
NOTE: Use proper ESD techniques while making adjustments under cover.
|
| Indicators | 2 LED Indicators:Green and Yellow
Green ON steady:power ON
Yellow ON steady:light sensed signal strength indicator (Banner's Aid Alignment Indicator Device—the faster the flash, the more light is received)
|
| Construction | Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover.
|
| Environmental Rating | NEMA 1; IEC IP50
|
| Connections | PVC-jacketed 2 m or 9 m attached cable or integral 4-pin Pico-style QD. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-10° to +55° C
Storage Temperature:-20° to +85° C
Relative humidity:90% @ 50° C
|
| Installation | 35 mm DIN rail or included mounting bracket
|