| Supply Voltage and Current | Fixed-field (DC):10 to 30V dc (10% max. ripple) @ less than 40 mA (exclusive of load) Fixed-field (AC/DC):24 to 250V ac, 50/60 Hz or 12 to 250V dc (1.0 watt max.) Adjustable-field:10 to 30V dc (10% max. ripple within specified limits) at < 80 mA at 10V dc; < 40 mA at 30V dc |
|---|---|
| Range | Fixed-field:200, 400 or 600 mm cutoff, depending on model Adjustable-field:adjustable between 50-600 mm |
| Supply Protection Circuitry | Protected against reverse polarity, over voltage and transient voltages |
| Output Configuration | DC models: Bipolar: One NPN (current sinking) and one PNP (current sourcing); light operate (LO) or dark operate (DO) selectable or configurable, depending on model AC/DC models:SPDT (Single-Pole Double-Throw) electromechanical relay output |
| Output Rating | Fixed-field (DC): - 100 mA max. each output @ 25° C - OFF-state leakage (NPN):less than 200 µA @ 30V dc - OFF-state leakage (PNP):less than 10 µA - ON-state saturation voltage (NPN):less than 1.6V @ 100 mA - ON-state saturation voltage (PNP):less than 2.0V @ 100 mA Fixed-field (AC/DC): - Max. switching power (resistive load):150 W, 1250 VA - Max. switching voltage (resistive load):250V ac; 125V dc - Max. switching current (resistive load):5 A @ 250V ac; 5 A @ 30V dc derated to 200 mA @ 125V dc - Min. voltage and current:5V dc, 10 mA - Mechanical life of relay:50 million operations - Electrical life of relay at full resistive load:100,000 operations Adjustable-field: - 100 mA max. load (derate approximately 1 mA/° C above 30° C) - OFF-stage leakage current:less than 5 µA @ 30V dc - ON-stage saturation voltage (NPN):less than 1.5V @ 100 mA - ON-state saturation voltage (PNP):less than 2.0V @ 100 mA |
| Output Protection Circuitry | DC models:Protected against output short-circuit, continuous overload, transient over-voltages and false pulse on power-up |
| Output Response Time | Fixed-field (DC):2 milliseconds ON/OFF; 100 ms delay on power-up; outputs do not conduct during this time Fixed-field (AC/DC):15 milliseconds ON/OFF; 100 ms delay on power-up; outputs do not conduct during this time Adjustable-field: 5 millisecond ON/OFF; 200 ms delay on power-up; outputs do not conduct during this time |
| Repeatability | Fixed-field (DC):500 microseconds Adjustable-field:750 microseconds |
| Adjustments | Fixed-field (DC): Light operate:High (open or 5 to 30V)* Dark operate: Low (0 to 3V)* Adjustable-field: Four-turn adjustment screw sets cutoff distance between min. and max. positions, clutched at both ends of travel |
| Indicators | Large, oval LED indicator on back: * Yellow ON steady: output conducting 2 LED indicator on top: Green and Yellow * Green ON steady: power ON * Yellow ON steady: light sensed * Yellow flashing:marginal excess gain (1.0-1.5x excess gain) Adjustable-field: 2 Indicator LEDs on sensor top: * Green ON steady: Power ON * Yellow ON steady: Light sensed (excess gain > 1.5x) * Yellow flashing: Marginal sensing condition (excess gain < 1.5x) 2 Indicator LEDs on sensor back: * Small Blue/Red End-of-travel (EOT) LED * Large Yellow Output LED |
| Construction | Fixed Field: PC/ABS housing with acrylic lens cover Adjustable-field: ABS housing, acrylic lens cover; 2.5 mm and 3 mm mounting hardware included QD models: nickel-plated brass |
| Environmental Rating | IP67; NEMA 6 |
| Connections | DC models:5-conductor 2 m or 9 m attached PVC cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. AC/DC models:2 m or 9 m 5-wire PVC cable Adjustable-field: 2 m (6.5') 5-wire PVC cable, 9 m (30') PVC cable, or 5-pin Integral QD or Euro-style 150 mm (6 in.) pigtail QD, depending on model |
| Operating Conditions | Fixed-field: Temperature:-20 to +70° C Relative humidity:90% @ 50° C (non-condensing) Adjustable-field: Temp: –20° to +60° C (–4° to 140° F) Relative Humidity: 95% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | DC models:All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz max., double amplitude 0.06-inch acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Certifications | Adjustable-field: CE AC/DC: UL, cULus Listed |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | WORLD-BEAM QS30 Adjustable-Field Sensors with Background Suppression | 148757 | 874K | Download Email |
| 2. | WORLD-BEAM QS30 Adjustable-Field Series | 111384 | 561K | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | WORLD-BEAM QS30 Series, ac/dc models | 119168 | 310K | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | Adjustable-Field Sensors Flyer | 153639 | 2.5MB | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | QS30AF Background Suppr - French | FD230 | 2.5MB | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | QS30AF Background Suppr - German | GD230 | 2.5MB | Download Email |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Banner has more than 2,000 distributors worldwide - ready to help you. Enter a U.S. zip code