A manually operated safety control device which, when continuously activated and used in conjunction with a separate actuating control, will allow the machine to function in manual operating mode.
| Supply Voltage and Current | 250V ac/dc |
|---|---|
| Impulse Withstand Voltage | 3-position switch: 2.5 kV Momentary pushbutton: 1.5 kV |
| Output Contact Ratings | See table on pg. 11 of data sheet. |
| Rated Thermal Current (Ith): | 2.5 A* *For the following operating temperatures: 40°C ≤ 50°C: 2 A ( 4 contacts under load) 50°C ≤ 60°C: 1.5 A ( 3 contacts under load) |
| Contact Resistance | 100 mohm max. |
| Insulation Resistance | Live to dead metal parts: 100 Mohm min. Positive to negative live parts: 100 Mohm min. |
| Recommended Wire/Cable Size | Wire: 0.14 to 1.5 mm² (25 AWG to 16 AWG) Cable: ø 7 to 13 mm M20 conduit |
| Short Circuit Protection | 250V / 10A fast blow fuse (IEC 60127-1) Conditional short circuit current: 50 A (250V) |
| Vibration Resistance | Operating extremes: 5 to 55 Hz, half amplitude 0.5 mm minimum Damage limits: 16.7 Hz, half amplitude 1.5 mm minimum |
| Shock Resistance | Operating extremes:150 m/s² (15 G) Damage limits: 1,000 m/s² (100 G) |
| Direct Opening | (Terminals 5 and 6 models ED1G-L21SM-1N and ED1G-L21SMB-1N) Actuating Force: 70 N minimum Travel: 4.7 mm minimum |
| Date code format | YYWWX: 2-digit year, 2-digit week, X internal code |
| Mechanical Life | Positions 1 & 2 only: 1,000,000 operations minimum Positions 1, 2 & 3: 100,000 operations minimum Operating frequency: 1,200 operations per hour maximum |
| Electrical Life | 100,000 operations minimum at rated load |
| Pollution Degree | 3 |
| Terminal Pulling Strength | 20 N minimum |
| Terminal Screw Torque | 0.5 to 0.6 Nm |
| Operating Conditions (indoor use only) | Temperature: –10° to +60° C (no freezing) Humidity: 45 to 85% RH max. (no condensation) Storage Temperature: –40° to +80° C (no freezing) |
| Construction | Polyamide housing and cable gland, NBR/PVC polyblend rubber grip switch boot; model ED1G-L21SM-1N meets IP66; other models meet IP65 |
| Applicable Standards | Design Standards: IEC 60947-5-1, EN 60947-5-1, JIS C8201-5-1, UL 508, CSA C22.2 No. 14, GS-ET-22 Application Standards: ISO 12100/EN ISO 12100, IEC 60204-1/ EN 60204-1, ISO 11161/EN ISO11161, ISO10218-1/EN ISO10218-1, ANSI/RIA/ISO 10218-1, ANSI NFPA 79, ANSI/RIA R15.06, ANSI B11.19, ISO 13849-1/EN ISO 13849-1 |
| Certifications | CE, cULus listed, Ind. Cont. Eq. 858T E71083 |
| Ratings approved by Safety Agencies | TÜV rating: AC-15 250V ac 0.5A; DC-13 125V dc 0.1A; Applicable EC Directives: LOW Voltage Directive (2006/95/EC), Machinery Directive (2006/42/EC); Applicable EC Standard(s): EN60947-5-1, GS-ET-22 UL, c-UL rating: 250V ac, 0.5A Pilot Duty; 125V dc, 0.1A Pilot Duty, Ambient Temperature +40°C, Environmental Rating Type 4X, Indoor Use Only. UL has only investigated this device for shock and fire to UL508. |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | ED1G Enabling Device | 151822 | 1.4MB | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | F142 Safety Solutions 16 Page - UK English | F142-Safety | 2.2MB | Download Email |
| Document Name | Part Number | File Size | Action | |
|---|---|---|---|---|
| 1. | F142 Safety Solutions 16 Page - French | FR-F142-Safety | 2.3MB | Download Email |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Is your line competitive? Innovative, high-quality solutions for every phase of production. Enjoy increased accuracy, greater productivity, cost savings.
Learn more »Banner has more than 2,000 distributors worldwide - ready to help you. Enter a U.S. zip code