| Supply Voltage and Current | 10 to 30V dc (10% max. ripple @ 10% duty cycle) @ 35 mA (exclusive of load) |
|---|---|
| Range | Laser Polarized Retroreflective:0.2 to 18 m, range is specified using one model BRT-36X40BM retroreflector Laser Diffuse (Class 1):400 mm Laser Diffuse (Class 2):800 mm |
| Beam Size Aperture | Laser Polarized Retroreflective:Approx. 3 mm Laser Diffuse:Approx. 2 mm |
| Supply Protection Circuitry | Protected against reverse polarity, over voltage and transient voltages |
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing); light operate (LO) or dark operate (DO) selectable or configurable, depending on model |
| Output Rating | 150 mA max. load
OFF-state leakage:less than 10 µA @ 30V dc ON-State saturation voltage: NPN:less than 1.0V @ 150 mA load
PNP:less than 2.0V @ 150 mA load
|
| Output Protection Circuitry | Protected against output short-circuit, continuous overload, transient over-voltages and false pulse on power-up |
| Output Response Time | 500 microseconds |
| Delay at Power-up | 1 second max.; outputs do not conduct during this time. |
| Repeatability | 70 microseconds |
| Adjustments | Laser Polarized Retroreflective: 2 Push Buttons and Remote Wire:Push-button programming; manually adjust (+/-) cutoff; NO/NC or LO/DO and OFF-delay configuration options; and push-button lockout using remote wire Laser Diffuse: 2 Push Buttons and Remote Wire::Expert TEACH programming (two-point static and single-point static); manually adjust (+/-) cutoff; NO/NC or LO/DO and OFF-delay configuration options; and push-button lockout using remote wire |
| Indicators | 8-segment Red bargraph:distance relative to cutoff point (or switch-point for Diffuse) 2 LED indicators on top:Green and Yellow Green:power ON
Yellow:output conducting
|
| Construction | PC/ABS housing with acrylic lens cover |
| Environmental Rating | IP67; NEMA 6 |
| Connections | 5-conductor 2 m or 9 m attached PVC cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-10 to +50° C Relative humidity:90% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz max., double amplitude 0.06-inch acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |