Precise long-range measurement sensors with analog and discrete output
| Supply Voltage and Current | 12 to 24V dc (10% max. ripple); 108 mA max. @ 24V dc or [2600/V dc] mA |
|---|---|
| Sensing Range | Diffuse: 90% white card:0.3 to 5 m
18% gray card:0.3 to 3 m
6% black card:0.3 to 2 m
Retroreflective:0.5 to 50 m, range is specified using one model BRT-TVHG-8x10P retroreflector |
| Sensing Beam | Typical beam dia.:6 mm @ 3 m Typical laser lifetime:75,000 hours Diffuse:658 nm visible red IEC and CDRH Class 2 laser; 0.5 mW max. radiant output power Retroreflective:658 nm visible red IEC and CDRH Class 1 laser; 0.15 mW max. radiant output power |
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Output Configuration | One discrete output and one analog output
Discrete (switched) output: SPST solid-state switch:selectable NPN (current sinking) or PNP (current sourcing) Analog output:0 to 10V dc or 10 to 0V dc (voltage sourcing) or 4 to 20 mA or 20 to 4 mA (current sourcing), depending on model |
| Output Rating | Discrete (switched) output:100 mA max. OFF-state leakage current:less than 5 µA Output saturation: NPN:less than 200 mV @ 10 mA; less than 600 mV @ 100 mA
PNP:less than 1.2V @ 10 mA; less than 1.6V @ 100 mA
Analog voltage output:2.5 k ohms min. load impedanceAnalog current output:1 k ohms max. @ 24V; max. load resistance = [Vcc-4.5/0.02 ohms] |
| Output Protection Circuitry | Protected against short circuit conditions |
| Output Response Time | Discrete outputs: Fast:1 millisecond ON/OFF
Medium:10 milliseconds ON/OFF
Slow:100 milliseconds ON/OFF
Diffuse analog output (-3 dB):Fast:450 Hz (1 millisecond average/1 millisecond update rate)
Medium:45 Hz (10 milliseconds average/2 millieconds update rate)
Slow:4.5 Hz (100 milliseconds average/4 millisecond update rate)
Retroreflective analog output (-3 dB):Fast:114 Hz (6 milliseconds average/1 millisecond update rate)
Medium:10 Hz (48 milliseconds average/1 millisecond update rate)
Slow:2.5 Hz (192 milliseconds average/1 millisecond update rate)
|
| Delay at Power-up | 1 second; outputs do not conduct during this time. |
| Color Sensitivity | Diffuse: 90% white to 18% gray:less than 10 mm
90% white to 6% black:less than 20 mm
|
| Analog Linearity | Diffuse:±30 mm from 0.3 to 1.5 m; ±20 mm from 1.5 to 5 m; specified @ 24V dc, 22° C using a 90% reflectance white card Retroreflective:±60 mm from 1.5 to 50 m (0.12% of full scale); specified @ 24V dc, 22° C using supplied BRT-TVHG-8X10P |
| Discrete Output Hysteresis | Diffuse: Fast:10 mm
Medium:5 mm
Slow:3 mm
Retroreflective:Fast:20 mm
Medium:10 mm
Slow:6 mm
|
| Temperature Effect | Diffuse:less than 2 mm/° C Retroreflective:less than 3 mm/° C |
| Minimum Window Size | Diffuse:20 mm Retroreflective:40 mm |
| Remote TEACH Input | 18 k ohms (65 k ohms @ 5V dc) |
| Remote TEACH | To TEACH:connect yellow wire to +5 to 24V dc To disable:connect yellow wire to 0 to +2V dc (or open connection) |
| Adjustments | Response speed:Push button toggles between fast, medium and slow (see Output Response Time) Window limits (analog or discrete):TEACH-mode programming of near and far window limits. Limits may also be taught remotely using TEACH input. Analog output slope:The first limit taught is assigned to minimum output current or voltage (4 mA or 0V dc) |
| Laser Control | Connect red wire to +5 to 24V dc to enable laser beam; connect to 0 to +1.8V dc (or open connection) to disable; when sensor is powered laser enable time is 100 millisecond delay on enable, when sensor is powered. |
| Indicators | Green Power ON LED:indicates when power is ON, overloaded output and laser status Yellow Output LED:indicates when discrete load output is conducting Red Signal LED:indicates target is within sensing range and the condition of the received light signal Yellow Speed LED:indicates the response speed setting Red/Yellow TEACH LEDs:in programming mode; indicate active output(s) |
| Construction | Housing:ABS/polycarbonate blend Window:acrylic Quick-disconnect:ABS/polycarbonate blend |
| Environmental Rating | IP67; NEMA 6 |
| Connections | 7-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 8-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:0° to +50° C Relative humidity:90% @ 50° C (non-condensing) |
| Application Notes | • For best accuracy, allow 30-minute warm-up before programming or operating • Retroreflective performance specifications are based on use with supplied BRT-TVHG-8X10P high grade target. Results may vary with other retroreflective target materials. |