| Supply Voltage and Current | 10 to 30V dc (10% max. ripple)
Opposed Emitters:25 mA (exclusive of load) Opposed Receivers:20 mA (exclusive of load) Polarized Retroreflective:30 mA (exclusive of load) Fixed-field:35 mA (exclusive of load) |
|---|---|
| Range | Opposed:20 m Polarized Retroreflective:2 m, range is specified using one model BRT-3 retroreflector Fixed-field:0-25, 0-50 or 0-100 mm cutoff, depending on models |
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Output Rating | 150 mA max. (each); the total load may not exceed 150 mA
OFF-state leakage:less than 1 µA @ 30V dc ON-state saturation voltage:less 1V @ 10 mA dc; less than 1.5V @ 150 mA dc |
| Output Configuration | Sensing Output:PNP (current sourcing), light operate Alarm Output:PNP (current sourcing), normally open and conducts whenever the sensor's excess gain drops to 1-1.5x in light condition |
| Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short-circuit of outputs |
| Output Response Time | Response time is independent of signal strength
Opposed:3 millisecond ON; 1.5 milliseconds OFF Polarized Retroreflective and Fixed-field:3 milliseconds ON/OFF |
| Delay at Power-up | 100 milliseconds; outputs do not conduct during this time. |
| Repeatability | Repeatability is independent of signal strength
Opposed:375 microseconds Polarized Retroreflective and Fixed-field:750 microseconds |
| Indicators | 2 LED Indicators:Green and Yellow Green ON steady:power to sensor is ON
Green flashing:output is overloaded
Yellow ON steady:normally open output is conducting
Yellow flashing:marginal excess gain (1-1.5x) in light condition
|
| Construction | Thermoplastic polyester housing with polycarbonate or acrylic lenses. One jam nut is included with each sensor. |
| Environmental Rating | Leakproof design is rated NEMA 6P; IEC IP67 |
| Connections | 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-40° to +70° C Relative humidity:90% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »“I’m delighted with Banner’s SureCross wireless system. It gives us comprehensive monitoring and control in previously inaccessible locations. And it’s easy to expand and relocate as needed.”
Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code