Q25 DC Series

Product image

Overview

  • Specially designed EZ-BEAM style optics and electronics for reliable sensing without adjustments
  • 10 to 30V dc with NPN or PNP outputs
  • 25 mm plastic housing with 18 mm threaded mounting base
  • Available in opposed, polarized retroreflective and fixed-field sensing modes
  • Marginal gain indicator with alarm output
  • Dual-LED multi-function indicators for monitoring sensor performance

Product Specifications

RangeOpposed:20 m
Polarized Retroreflective:2 m, range is specified using one model BRT-3 retroreflector
Fixed-field:0-25, 0-50 or 0-100 mm cutoff, depending on model
Supply Voltage and Current10 to 30V dc (10% max. ripple) Opposed Emitters:25 mA (exclusive of load)
Opposed Receivers:20 mA (exclusive of load)
Polarized Retroreflective:30 mA (exclusive of load)
Fixed-field:35 mA (exclusive of load)
Supply Protection CircuitryProtected against reverse polarity and transient voltages
Output ConfigurationSolid-state complementary (SPDT) dc switch:NPN (current sinking) or PNP (current sourcing), depending on model. The dark operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
Output Rating150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA OFF-state leakage current::less than 1 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
Output Protection CircuitryProtected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response TimeResponse time is independent of signal strength. Opposed:3 milliseconds ON; 1.5 milliseconds OFF
Polarized Retroreflective and Fixed-field:3 milliseconds ON/OFF
Delay at Power-up100 milliseconds; outputs do not conduct during this time.
RepeatabilityRepeatability is independent of signal strength. Opposed:375 microseconds
Polarized Retroreflective and Fixed-field:750 microseconds
Indicators2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Green flashing:output is overloaded
Yellow ON steady:light-operate output is energized
Yellow flashing:marginal excess gain (1-1.5x) in light condition, LO output is energized
ConstructionThermoplastic polyester housing with polycarbonate or acrylic lenses. One jam nut is included with each sensor.
Environmental RatingLeakproof design rated NEMA 6P; DIN 40050 (IP69K)
Connections2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
Operating ConditionsTemperature:-40° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
Vibration and Mechanical ShockAll models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)