| Supply Voltage and Current | 20 to 250V ac (50/60 Hz)
Average current:20 mA Peak current:200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac |
|---|---|
| Range | Opposed:20 m Polarized Retroreflective:2 m, range is specified using one model BRT-3 retroreflector Fixed-field:0-25, 0-50 or 0-100 cutoff, depending on model |
| Supply Protection Circuitry | Protected against transient voltages |
| Output Configuration | SPST solid-state ac switch; three-wire hookup: Light operate (LO) or dark operate (DO), depending on model
Light operate:Output conducts when the sensor sees its own (or the emitter’s) modulated light Dark operate:Output conducts when sensor sees dark |
| Output Rating | 300 mA max. (continious); Fixed-field derate 5 mA/° C above +50° C
Inrush capability:1 A for 20 milliseconds, non-repetitive OFF-state leakage current:less than 100 µA ON-state voltage drop:3V @ 300 mA ac; 2V @ 15 mA ac |
| Output Protection Circuitry | Protected against false pulse on power-up |
| Output Response Time | Response time is independent of signal strength.
Opposed:16 milliseconds ON; 8 milliseconds OFF Polarized retroreflective and Fixed-field:16 milliseconds ON/OFF |
| Delay at Power-up | 100 milliseconds |
| Repeatability | Repeatability is independent of signal strength
Opposed:2 milliseconds Polarized Retroreflective and Fixed-field:4 milliseconds |
| Indicators | 2 LED Indicators:Green and Yellow Green ON steady:power to sensor is ON
Yellow ON steady:sensor sees light
Yellow flashing:marginal excess gain (1-1.5x) in light condition
|
| Construction | Thermoplastic polyester housing with polycarbonate or acrylic lenses. One jam nut is included with each sensor. |
| Environmental Rating | Leakproof design rated NEMA 6P; DIN 40050 (IP69K) |
| Connections | 2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-40° to +70° C Relative humidity:90% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max, double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »“I’m delighted with Banner’s SureCross wireless system. It gives us comprehensive monitoring and control in previously inaccessible locations. And it’s easy to expand and relocate as needed.”