A Node provides sensing capability in a remote area and communicates data back to a Gateway.
| General | Power:+10 to 30V dc or 3.6 to 5.5V dc low power option Power consumption:less than 1.4 W @ 24V dc Indicators:Two LED, bicolor Switches:Two push buttons Display:Six character LED Mounting:#10 or M5 (M5 hardware included) M5 fasteners—max. tightening torque:0.56 N/m (5 in/lbf) Case material:polycarbonate Weight:0.26 kg External cable gland:four PG-7 type, One 1/2—NPT type Cable glands, max. tightening torque:0.56 N/m (5 in/lbf) |
|---|---|
| Radio | Range with standard 2 dB antenna*: 900 MHz models:up to 4.8 km (3 miles)
2.4 GHz models:up to 3.2 km (2 miles)
Frequency:900 MHz models::902 -928 MHz ISM band
2.4 MHz models:2.4 - 2.4835 GHz ISM band
Transmit power:900 MHz models:21 dBm conducted
2.4 GHz models:18 dBm conducted, 20 dBm EIRP max.
Spread spectrum technology:Frequency Hopping Spread Spectrum (FHSS)Antenna connector:ext. reverse polarity SMA - 50 ohms Antenna—max. tightening torque:0.45 N/m (4 in/lbf) Link timeout:defined by Gateway *Note:The range depends upon the environment and line of site. High-gain antennas are available to increase the range. |
| Inputs | Analog and discrete models: Discrete inputs:two sinking
Discrete rating:3 mA max. current @ 30V dc
Discrete 1, 2 sample rate:125 milliseconds
Discrete 1, 2 report rate:On change of state
Discrete ON condition:less than 0.7V
Discrete OFF condition:greater than 2V or Open
Analog inputs:0-20 mA
Switched power for analog input 1:defaults SP1: 15V @ 150 mA for 500 milliseconds every 15 minutes
Analog 1 sample rate:15 minutes
Analog 1 report rate:15 minutes
Analog 2 sample rate:1 second
Analog 2 report rate:15 seconds or On Change of State (1% change in value)
Thermocouple models:Discrete inputs:two sinking
Discrete rating:3 mA max. current @ 30V dc
Discrete 1, 2 sample rates:1 second
Discrete 1, 2 report rates:On change of State
Discrete ON condition:less than 0.7V
Discrete OFF condition:greater than 2V or Open |
| Outputs | Analog/discrete and thermocouple models: Discrete outputs:two NMOS sinking
Discrete rating:less than 10 mA max. current @ 30V dc
Discrete update rate:up to 1 per second
Discrete ON condition:less than 0.7V
Discrete OFF condition:open
State following timeout:de-energized (OFF)
|
| Thermocouple | Thermocouple models only: Thermocouple inputs:three
Thermocouple input sample rate:1 second
Thermocouple input report rate:periodic, 16 seconds
Thermistor inputs:one, model number BWA-THERMISTOR-001
Resolution:0.1° C, 24-bit A/D converter
Thermocouple accuracy:0.1%of full scale reading +0.8° C
Thermistor accuracy:0.4° C (10 to 50° C); up to 0.8° C (-40 to +85° C)
|
| Environmental | Environmental rating*:IEC IP67; NEMA 6 Operating temperature**:-40 to +85° C (electronics); -20 to +80° C (LCD) Relative humidity:95% (non-condensing) Shock and vibration:IEC IEC 68-2-6 and IEC 68-2-7 Shock:30 g, 11 millisecond half-sine wave, 18 shocks
Vibration:0.5 mm p-p, 10-60 Hz
*Note 1:Please refer to the SureCross DX80 Quick Start Guide, Banner part number 128185, for installation and waterproofing instructions.*Note 2:Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device. |
| Compliance | 900 MHz models:FCC ID TGUDX80 - This device complies with FCC Part 15, Subpart C, 15.247 2.4 GHz models:FCC ID UE300DX80-2400 - This device complies with FCC Part 15, Subpart C, 15.247. ETSI/EN: In accordance with EN 300 328: V1.7.1 (2006-05) |
| Product Specifications and Modifications Disclaimer | All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of products, prior to their order, without notice. |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »Banner has more than 3,000 distributors—ready to help you. Enter your U.S. city or zip.