Overview

  • Available in 14 mm resolution for finger, hand and ankle protection or 30 mm resolution for hand and ankle protection
  • Made from nickel-plated static-dissipating materials
  • Operates in ranges from 0.1 m to 6 m (14 mm models) and 0.1 m to 18 m (30 mm models)
  • Offers optional reduced resolution (former fixed blanking) to ignore tooling or constant inflow of materials
  • Displays operating status, configuration and error codes
  • Includes blocked beam zone indicators
  • Features user configurable trip or latch outputs and Scan Code 1 or 2
  • Resists impact, twisting and abusive environments with a durable aluminum housing and metal end caps
  • Offers optional cascading to create a multi-light-screen-system that responds to a single stop command

Product Specifications

Supply Voltage at the Device24V dc ±15% (SELV), ±10% max. ripple

(The external voltage supply must be capable of buffering brief mains interruptions of 20 milliseconds, as specified in IEC/EN 60204-1).
Supply CurrentEmitter:100 mA max.
Receiver:275 mA max., exclusive of OSSD1 and OSSD2 loads (up to an additional 0.5 A each)
Resolution† and Operating Range (†No blanking enabled)14 mm resolution models:0.1 to 6 m
30 mm resolution models:0.1 to 18 m
Range decreases with use of mirrors and/or lens shields:
Lens shields:approximatel 10% of range per shield
Glass surface mirrors:approximately 8% less range per mirror
Response TimeDependent on number of sensing beams 10 beams:9 milliseconds
20 beams:11 milliseconds
30 beams:13 milliseconds
40 beams:15 milliseconds
50 beams:17 milliseconds
60 beams:19 milliseconds
70 beams:21 milliseconds
80 beams:23 milliseconds
90 beams:25 milliseconds
100 beams:27 milliseconds
110 beams:30 milliseconds
120 beams:32 milliseconds
140 beams:36 milliseconds
160 beams:40 milliseconds
180 beams:43 milliseconds
200 beams:48 milliseconds
220 beams:52 milliseconds
240 beams:56 milliseconds
CSSI Response Time (SLSC.. cascade models only)Response time for a cascade receiver due to opening contacts at the cascade interface (CSSI) is 40 milliseconds max. (contacts must open for 60 milliseconds min.).
Remote Test Input (Optional - available only SLSE..-..Q5 emitters)Test Mode is activated either by applying a low signal (less than 3V dc) to emitter TEST #1 terminal for a minimum of 50 milliseconds, or by opening a switch connected between TEST #1 and TEST #2 for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked condition. A high signal at TEST #1 deactivates Test Mode. (See p/n 112852 for more information.)
High signal:10 to 30V dc
Low signal:0 to 3V dc
Input current:35 mA inrush, 10 mA max.
Wavelength of Emitter ElementsInfrared LEDs, 950 nm at peak emission
EDM Input+24V dc signals from external device contacts can be monitored (one-channel, two-channel or no monitoring) using EDM1 and EDM2 terminals in the receiver. Monitored devices must respond within 200 milliseconds of an output change.
High signal:10 to 30V dc @ 30 mA typical
Low signal:0 to 3V dc
Dropout time:200 milliseconds max.
Reset InputThe Reset input must be high for 0.25 to 2 seconds and then low to reset the receiver.
High signal:10 to 30V dc @ 30 mA typical
Low signal:0 to 3V dc
Closed switch time:0 .25 to 2 seconds
Safety OutputsTwo redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs.

(Use optional interface modules for ac or larger dc loads.)

Capable of the Banner “Safety Handshake”.
ON-state voltage:greater than or equal to Vin-1.5V dc
OFF-state voltage:1.2V dc max. (0-1.2V dc)
Max. load capacitance:1.0 µF
Max. load inductance:10 H
Leakage current:0.50 mA max.
Cable resistance:10 ohms max.
OSSD test pulse width:100 to 300 microseconds
OSSD test pulse period:5 to 27 milliseconds (varies with number of beams)
Switching current:0-0.5 A
Controls and AdjustmentsEmitter:
Scan Code selection:2-position switch (code 1 or 2). Factory default position is code 1.
Receiver:
Scan Code selection:2-position switch (code 1 or 2). Factory default position is code 1.
Trip/Latch Output selection:Redundant switches. Factory default position is T (Trip)
EDM/MPCE Monitor selection:2-position switch selects between 1- or 2-channel monitoring. Factory default position is 2.
Reduced Resolution (2-beam Floating Blanking):Redundant switches to enable. Factory default is OFF.
Short Circuit ProtectionAll inputs and outputs are protected from short circuits to +24V dc or dc common
Electrical Safety Class (IEC 61140: 1997)III
Safety RatingType 4 per IEC 61496-1, -2; Category 4 per ISO 13849-1 (EN 954-1)
Ambient Light ImmunityGreater than 10,000 lux @ 5° angle of incidence
Effective Aperture Angle (EAA)Meets Type 4 requirements per IEC 61496-2, ±2.5° @ 3 m
EnclosureMaterial:Extruded aluminum housing with yellow polyester powder finish standard and well-sealed, rugged die-cast zinc end caps, acrylic lens cover, copolyester access cover. End caps on silver models are also nickel-plated. ESD-safe models have static-dissipative acrylic lens cover.
Environmental RatingIEC IP65
Status IndicatorsEmitter:
One bicolor (Red/Green) status indicator:indicates operating mode, lockout or power OFF condition
7-segment Diagnostic indicator:indicates proper operation, scan code or error code
Receiver:
Yellow Reset indicator:indicates whether system is ready for operation or requires a reset
Bicolor (Red/Green) Status indicator:indicates general system and output status
Bicolor (Red/Green) Zone Status indicators:indicates condition (clear or blocked beam) of a defined group of beams
7-segment Diagnostic indicator:indicates proper operation, scan code or error code, total number of blocked beams
Mounting HardwareEmitter and receiver each are supplied with a pair of swivel end-mounting brackets. Models longer than 900 mm also include a swivel center-mount bracket. Mounting brackets are 8-gauge cold-rolled steel, black zinc finish.
Shock and VibrationEZ-SCREEN components have passed vibration and shock tests according to IEC 61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm single amplitude (0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles).
Operating ConditionsTemperature:0° to +55° C
Relative humidity:95% (non-condensing)

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

"No more costly wiring runs"

“I’m delighted with Banner’s SureCross wireless system. It gives us comprehensive monitoring and control in previously inaccessible locations. And it’s easy to expand and relocate as needed.”

Worldwide Distributors

Banner has more than 2,000 distributors worldwide — ready to help you.


Find international distributors