ES-FA-6G Safety Module

Product image

Overview

  • Monitors external safety devices for contact failure or wiring fault
  • Offers 24V ac/dc supply voltage
  • Provides three normally open (NO) immediate safety outputs rated at 6 amps
  • Includes one normally closed (NC) non-safety auxiliary outputs
  • Resets automatically or manually
  • Features a 35 millisecond response time
  • Meets US and international standards
  • Rated IEC IP40; NEMA 1

Product Specifications

Supply Voltage and Current24V ac/dc, ±10%; 50/60 Hz Power Consumption:approx. 0.75 VA / 2 W
Supply Protection CircuitryProtected against transient voltages and reverse polarity
Output ConfigurationOutput (K1 & K2):three redundant (total of six) safety relay (forced-guided) contacts—AgSn02, plus one normally-closed auxiliary monitor output
Contact rating:
Max. voltage:250V ac/dc
Max. current:6 A ac/dc
Min. current:30 mA @ 10V dc
Max. power:150 W (1500 VA)
Mechanical life:10,000,000 operations
Electrical life:100,000 at full resistive load
Note:Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts.
Output Response Time35 milliseconds typical
Input RequirementsInput switch must have a normally-closed contact capable of switching 40 to 100 mA @ 13 to 27V ac/dc.



Reset switch must have one normally-open contact capable of switching 20 to 30 mA @ 13 to 27V ac/dc.
Status Indicators3 Green LED indicators :
Power:power is supplied to safety module
Channel 1:K1 energized
Channel 2:K2 energized
ConstructionPolycarbonate housing
Environmental RatingRated IEC IP40; NEMA 1
MountingMounts to standard 35 mm DIN-rail track. Safety module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better.
Vibration Resistance10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6
Operating ConditionsTemperature:0° to +50° C
Relative humidity:90% @ +50° C (non-condensing)

English

Data Sheets

Document Name Part Number File Size Download
1. ES-FA-6G Safety Module
(3 N.O. safety outputs, 24V ac/dc, 1 input)
55581 138K Download
2. ES-FA-9AA and ES-FA-11AA Safety Modules 60606 407K Download
3. ES-FL-2A Safety Module
(3 N.O. safety outputs, 24V ac/dc)
46262 87K Download
4. ES-GA/HA-5A Safety Modules
(4 N.O. safety outputs, 24V dc
51883 534K Download
5. ES-TA-3D1 Safety Module
(2 N.O. safety outputs, 24V dc, 6 inputs, DeviceNet)
51246 456K Download
6. ES-TA-3F1 Safety Module
(2 N.O. safety outputs, 24V dc, 10 inputs, DeviceNet)
53423 651K Download
7. ES-TN-14H5/6 Safety Modules
(8 N.O. safety outputs, 24V dc, adjustable delay)
68436 357K Download
8. ES-TN-1H5/6 Safety Modules
(4 N.O. safety ouptus, 24V dc, adjustable delay)
B_3102211 637K Download
9. ES-TN-1H5/6 Safety Modules
(4 N.O. safety ouptus, 24V dc, adjustable delay)
58697 366K Download
10. ES-TN-1Hx Safety Modules
(4 N.O. safety outputs, fixed delay)
61061 477K Download
11. ES-UA/VA-5A Safety Modules
(4 N.O. safety outputs, 12-24V dc/115 or 230V ac)
122365 1.6MB Download
12. GM-FA-10J Gate Monitoring Module
(24V ac/dc, 1 or 2 inputs)
60998 1.4MB Download
13. SI-MAG1C Magnetic Style Gate Monitoring Module
(24V ac/dc, 1 input)
49376 173K Download

Japanese

Data Sheets

Document Name Part Number File Size Download
1. ES-FA-6G Safety Module
(3 N.O. safety outputs, 24Vac/dc, 1 input) - Japanese
J30002M 298K Download
2. ES-FA-9AA Safety Module
(3 N.O safety outputs,24Vac/dc,1 or 2 inputs) - Japanese
J30014M 475K Download
3. ES-GA-5A/ES-HA-5A Safety Modules - Japanese J30001M 285K Download
4. ES-TN-14H5/6 Safety Modules
(8 N.O safety outputs, 24Vdc, adj delay) - Japanese
J30017M 590K Download
5. ES-TN-1H5/6 Safety Modules
(4 N.O. safety ouptus, 24V dc, adj delay) - Japanese
J30015M 728K Download
6. ES-TN-1Hx Safety Modules
(4 N.O. safety outputs, fixed delay) - Japanese
J30016M 683K Download
7. ES-UA-5A/ES-VA-5A Safey Modules - Japanese J30012M 613K Download

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

Looking for CAD Files?

Browse by model family or type in your model number to find STEP, IGS, DXF, or PDF files for your project.

Find them now »

Worldwide Distributors

Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code


Find international distributors