| Start-up reset time | 1.5 second
|
| Nominal voltage | 24V ac/dc, 50-60 Hz, no polarity
AC:UN +10 / -15%
DC:UN +/- 10%
Power consumption:approximately 4VA, 2.5 W
|
| Hysteresis | 6% typical
|
| PNP-Input Sensor | 24V dc (terminals S1s and S2s)
Input current max.:25 mA
Input current min.:3 mA
Min. pulse time:1 ms ON, 1 ms OFF
|
| Max. IPM at inputs S1s + S2s | 30,000
|
| Adjustable Setting Ranges (Impulses per Minute) | Model SSM-FM-11A10:5…40 ipm, 35…340 ipm, 300…2,700 ipm, or 1,200…10,500 ipm
Model SSM-FM-11A20:10…80 ipm, 80…650 ipm, 600…5,300 ipm, 2,400…20,000 ipm
|
| Output Response Time | Over-speed detection
Model SSM-FM-11A10:Range 5…10,500: tR = 700 ms typ.
Model SSM-FM-11A20:Range 10…20,000: tR = 350 ms typ.
|
| Output Configuration | Outputs K1 & K2:two redundant (total of four) safety relay N.O. (forced-guided) contacts—AgNi, gold flashed; one auxiliary N.C. contact—AgNi, gold flashed
Contact ratings (all N.O. and N.C. output contacts):2 normally open (N.O.) output channels and 1 normally closed (N.C.) aux. output
Current Rating:
Thermal Current Ith:4A
Switching Capacity to AC 15:3A / 230V ac for N.O. contacts (per IEC/EN 60 947-5-1); 2A / 230V ac for N.C. contact (per IEC/EN 60 947-5-1)
Min. voltage:15V ac/dc
Max. voltage:230V ac/dc
Min. current:30 mA ac/dc
Max. current:4 A
Min. power:0.45 W (0.45 VA)
Max. power:100 W (920 VA)
|
| Electrical life to AC15 at 2A, 230V ac | 3 x 100 000 operations min. (per IEC/EN 60 947-5-1)
|
| Mechanical life | 50 x 1,000,000 operations min.
|
| Indicators | 3 green LED indicators:Power On, Channel 1 active, and Channel 2 active
|
| Construction | Thermoplastic with VO behavior according to UL subject 94
|
| Environmental Rating | Housing IP40, Terminals IP20 (IEC/EN 60 529)
|
| Mounting | Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54) or better.
|
| Vibration Resistance | 10 to 55 Hz @ 0.35mm displacement per IEC 68-2-6
|
| Operating Conditions | Temperature:0 - 50 C (+32 to 122 F)
Max. Rel. Humidity:90% @ +50 C (non condensing)
|
| Certifications | Approvals are pending.
|