| Supply Voltage and Current | 250V ac/dc
|
| Impulse Withstand Voltage | 3-position switch: 2.5 kV
Momentary pushbutton: 1.5 kV
|
| Output Contact Ratings | See table on pg. 11 of data sheet.
|
| Rated Thermal Current (Ith): | 2.5 A*
*For the following operating temperatures:
40°C ≤ 50°C: 2 A ( 4 contacts under load)
50°C ≤ 60°C: 1.5 A ( 3 contacts under load)
|
| Contact Resistance | 100 mohm max.
|
| Insulation Resistance | Live to dead metal parts: 100 Mohm min.
Positive to negative live parts: 100 Mohm min.
|
| Recommended Wire/Cable Size | Wire: 0.14 to 1.5 mm² (25 AWG to 16 AWG)
Cable: ø 7 to 13 mm
M20 conduit
|
| Short Circuit Protection | 250V / 10A fast blow fuse (IEC 60127-1)
Conditional short circuit current: 50 A (250V)
|
| Vibration Resistance | Operating extremes: 5 to 55 Hz, half amplitude 0.5
mm minimum
Damage limits: 16.7 Hz, half amplitude 1.5 mm minimum
|
| Shock Resistance | Operating extremes:150 m/s² (15 G)
Damage limits: 1,000 m/s² (100 G)
|
| Direct Opening | (Terminals 5 and 6 models ED1G-L21SM-1N and ED1G-L21SMB-1N)
Actuating Force: 70 N minimum
Travel: 4.7 mm minimum
|
| Date code format | YYWWX: 2-digit year, 2-digit week, X internal code
|
| Mechanical Life | Positions 1 & 2 only: 1,000,000 operations minimum
Positions 1, 2 & 3: 100,000 operations minimum
Operating frequency: 1,200 operations per hour maximum
|
| Electrical Life | 100,000 operations minimum at rated load
|
| Pollution Degree | 3
|
| Terminal Pulling Strength | 20 N minimum
|
| Terminal Screw Torque | 0.5 to 0.6 Nm
|
| Operating Conditions (indoor use only) | Temperature: –10° to +60° C (no freezing)
Humidity: 45 to 85% RH max. (no condensation)
Storage Temperature: –40° to +80° C (no freezing)
|
| Construction | Polyamide housing and cable gland, NBR/PVC polyblend rubber grip switch boot; model ED1G-L21SM-1N meets IP66; other models meet IP65
|
| Applicable Standards | Design Standards: IEC 60947-5-1, EN 60947-5-1, JIS
C8201-5-1, UL 508, CSA C22.2 No. 14, GS-ET-22
Application Standards: ISO 12100/EN ISO 12100,
IEC 60204-1/ EN 60204-1, ISO 11161/EN ISO11161,
ISO10218-1/EN ISO10218-1, ANSI/RIA/ISO 10218-1,
ANSI NFPA 79, ANSI/RIA R15.06, ANSI B11.19, ISO
13849-1/EN ISO 13849-1
|
| Certifications | CE, cULus listed, Ind. Cont. Eq. 858T E71083
|
| Ratings approved by Safety Agencies | TÜV rating: AC-15 250V ac 0.5A; DC-13 125V dc
0.1A; Applicable EC Directives: LOW Voltage Directive
(2006/95/EC), Machinery Directive (2006/42/EC); Applicable
EC Standard(s): EN60947-5-1, GS-ET-22
UL, c-UL rating: 250V ac, 0.5A Pilot Duty; 125V dc,
0.1A Pilot Duty, Ambient Temperature +40°C, Environmental
Rating Type 4X, Indoor Use Only. UL has only
investigated this device for shock and fire to UL508.
|