| Supply Voltage and Current | 10 to 30V dc (10% max. ripple)
Opposed:50 mA total max. (exclusive of load)
Emitter:30 mA (exclusive of load)
Receiver:25 mA (exclusive of load)
Diffuse:25 mA (exclusive of load)
|
| Range | Opposed:510 mm
Diffuse:2.5 to 60 mm
|
| Supply Protection Circuitry | Protected against reverse polarity and continuous overload or short circuit
|
| Output Configuration | SPST solid-state switch:NPN (current sinking) or PNP (current sourcing), depending on model. Light operate (LO) or dark operate (DO), depending on model
|
| Output Rating | 150 mA max., continuous
OFF-state leakage current:100 µA @ 30V dc
ON-state saturation voltage:less than 200 mV @ 10 mA dc; less than 1 V @ 150 mA dc
|
| Output Protection Circuitry | Protected against false pulse on power-up
|
| Output Response Time | 1 millisecond ON/OFF, independent of signal strength
|
| Repeatability | 200 microseconds, independent of signal strength
|
| Indicators | 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Yellow ON steady:lights when sensor output is conducting (in light condition for light-operate models; in dark condition for dark-operate models)
|
| Construction | Black epoxy-painted die-cast zinc housing, polysulfone thermoplastic lens with two through-mounting holes to accommodate M3 (#4) hardware
|
| Environmental Rating | IEC IP67; Meets NEMA standards 1, 2, 4, 6 and 13
|
| Connections | 2 m or 9 m attached PVC cable, or 3-pin Pico-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:0° to 50° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Application Note | Be aware that optimum mechanical alignment of Q08 emitter/receiver pairs may not always result in optimum optical alignment. This may be a factor at longer sensing ranges. Once optimum mechanical alignment has been achieved, optical alignment can be optimized by tilting one unit (emitter or receiver) up/down and left/right. Look for center of the movement zone within which the receiver's output remains in the desired output state: ON for light-operate units and OFF for dark-operate units.
|