| Supply Voltage | 10 to 30V dc (10% maximum ripple) at less than 18 mA, exclusive of load
|
| Range | Opposed Mode (Visible Red):10 m
Opposed Mode (Infrared):15 m
Polarized Retro:4 m
Retro:6 m
Diffuse- Long Range (Visible Red):800 mm
Diffuse- Long Range (Infrared):1500 mm
Diffuse- Short Range:250 mm
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | 100 mA with short circuit protection
OFF-state leakage current:
NPN:< 10 μA sinking
PNP:< 200 μA sourcing
ON-state saturation voltage:
NPN:< 1.6V @ 100 mA
PNP:< 3.0V @ 100 mA
|
| Output Response Time | Opposed Mode:1 millisecond ON/600 microseconds OFF
All others:800 microseconds ON/OFF
NOTE:100 millisecond delay on power-up; outputs do not conduct during this time
|
| Repeatability | Opposed Mode:140 microseconds
All Others:155 microseconds
|
| Adjustments | Diffuse, Retroreflective, and Polarized Retroreflective models (only):Single-turn Sensitivity (Gain) adjustment potentiometer
|
| Indicators | Two LED Indicators: Power (green) and Signal (yellow)
Green ON steady:Power ON
Yellow ON steady:Light sensed
Green flashing:Output overloaded
Yellow flashing:Marginal excess gain (1 to 1.5X)
|
| Construction | Housing:ABS
Lenses:PMMA
Gain Adjuster:PBT
|
| Connections | 2 m (6.5') or 9 m (30') 4-wire PVC cable, 150 mm (6
|
| Operating Conditions | Temperature:–20° to +60° C (–4° to +140° F)
Relative Humidity:95% @ 50° C (non-condensing)
|
| Environmental Rating | IEC IP67 (NEMA 6) and 1200 PSI washdown NEMA ICS 5, Annex F-2002
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements method 201A (vibration: 10 to 60 Hz max., double amplitude 0.06
|
| Certifications | Approvals pending
|