Fixed-field (DC):100 mA max. each output @ 25° C
OFF-state leakage (NPN):less than 200 µA @ 30V dc
OFF-state leakage (PNP):less than 10 µA
ON-state saturation voltage (NPN):less than 1.6V @ 100 mA
ON-state saturation voltage (PNP):less than 2.0V @ 100 mA
Fixed-field (AC/DC):
Max. switching power (resistive load):150 W, 1250 VA
Max. switching voltage (resistive load):250V ac; 125V dc
Max. switching current (resistive load):5 A @ 250V ac; 5 A @ 30V dc derated to 200 mA @ 125V dc
Min. voltage and current:5V dc, 10 mA
Mechanical life of relay:50 million operations
Electrical life of relay at full resistive load:100,000 operations
Adjustable-field:150 mA max. load (derate approximately 1 mA/° C above 25° C)
OFF-stage leakage current:less than 50 µA @ 30V dc
ON-stage saturation voltage (NPN):less than 200 mV @ 10 mA; less than 1V @ 150 mA
ON-state saturation voltage (PNP):less than 1.25V @ 10 mA; less than 2V @ 150 mA
|