| Supply Voltage and Current | 10 to 30V dc (10% max. ripple @ 10% duty cycle) @ 35 mA (exclusive of load)
|
| Range | Laser Polarized Retroreflective:0.2 to 18 m, range is specified using one model BRT-36X40BM retroreflector
Laser Diffuse (Class 1):400 mm
Laser Diffuse (Class 2):800 mm
|
| Beam Size Aperture | Laser Polarized Retroreflective:Approx. 3 mm
Laser Diffuse:Approx. 2 mm
|
| Supply Protection Circuitry | Protected against reverse polarity, over voltage and transient voltages
|
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing); light operate (LO) or dark operate (DO) selectable or configurable, depending on model
|
| Output Rating | 150 mA max. load
OFF-state leakage:less than 10 µA @ 30V dc
ON-State saturation voltage:
NPN:less than 1.0V @ 150 mA load
PNP:less than 2.0V @ 150 mA load
|
| Output Protection Circuitry | Protected against output short-circuit, continuous overload, transient over-voltages and false pulse on power-up
|
| Output Response Time | 500 microseconds
|
| Delay at Power-up | 1 second max.; outputs do not conduct during this time.
|
| Repeatability | 70 microseconds
|
| Adjustments | Laser Polarized Retroreflective:
2 Push Buttons and Remote Wire:Push-button programming; manually adjust (+/-) cutoff; NO/NC or LO/DO and OFF-delay configuration options; and push-button lockout using remote wire
Laser Diffuse:
2 Push Buttons and Remote Wire::Expert TEACH programming (two-point static and single-point static); manually adjust (+/-) cutoff; NO/NC or LO/DO and OFF-delay configuration options; and push-button lockout using remote wire
|
| Indicators | 8-segment Red bargraph:distance relative to cutoff point (or switch-point for Diffuse)
2 LED indicators on top:Green and Yellow
Green:power ON
Yellow:output conducting
|
| Construction | PC/ABS housing with acrylic lens cover
|
| Environmental Rating | IP67; NEMA 6
|
| Connections | 5-conductor 2 m or 9 m attached PVC cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-10 to +50° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz max., double amplitude 0.06-inch acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
|