| Sensing Beam | 660 nm visible red LED
|
| Sensing Range and Use | 100 mm to 2 m (3.9
|
| Supply Voltage | 10 to 30V dc (10% max. ripple) @ 25 mA max current, exclusive of load
|
| Supply Protection Circuitry | Protected against reverse polarity, over voltage, and transient voltages
|
| Delay at Power-Up | 250 ms; outputs do not conduct during this time
|
| Output Configuration | Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN)
|
| Output Ratings | 150 mA maximum load; see Application Note 1
OFF-state leakage current:< 50 μA at 30V dc
NPN ON-state saturation voltage:< 200 mV @ 10 mA; < 1V @ 150 mA
PNP ON-state saturation voltage:< 1.25V @ 10 mA; < 2V @ 150 mA
|
| Output Protection | Protected against output short-circuit, continuous overload, transient over-voltages, and false pulse on power up
|
| Output Response Time | 500 microseconds
|
| Repeatability | 150 microseconds
|
| Adjustments | 2 push buttons and remote wire
*Easy push-button configuration and deterministic remote wire configuration
*Select from 3 standard thresholds based on object being detected
*Light Operate/Dark Operate configuration options selectable via push buttons or remote wire
*Push-button lockout (from remote wire only)
|
| Indicators | Green LED:Power ON and feedback on configuration and remote wire pulses
Amber LED:Output conducting or error condition (flashing)
3-Segment Red Signal Bargraph:Signal strength (excess gain), relative to switchpoint
5-Segment Amber Display:Sensor Configuration
|
| Construction | ABS plastic housing; acrylic lens cover
|
| Environmental Rating | Leakproof design rated IEC IP67 (NEMA 6); PW12 1200 PSI washdown
|
| Connections | 5-conductor 2 m (6.5’) PVC cable, 9 m (30’) PVC cable, 150 mm (6
|
| Operating Conditions | Temperature:-10° to +55°C (+14° to 122°F)
Max. relative humidity:95% @ 50°C (non-condensing)
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements; 30G, 11ms duration, half sine wave.
|
| Application Notes | 1. If supply voltage is > 24V dc, derate maximum output current 1 mA/°C above 25°C
|
| Certifications | CE Pending
|