| Supply Voltage and Current | Supplied by OMNI-BEAM power block
|
| Range | Opposed:45 m
Non-polarized Retroreflective:0.15 to 9 m, range is specified using one model BRT-3 retroreflector
Non-polarized Retroreflector (clear object):4 m
Polarized Retroreflective:0.3 to 4.5 m, range is specified using one model BRT-3 retroreflector
Diffuse (high speed):300 mm
Diffuse (high power):2 m
Convergent:38 mm
Plastic and Glass Fiber Optic:Range varies by sensing mode and fiber optics used
|
| Output Response Time | Opposed:2 milliseconds
Non-polarized Retroreflective, Polarized Retroreflective and Non-polarized Retroreflective (clear object):4 milliseconds
Diffuse (high speed):2 milliseconds
Diffuse (high power):15 milliseconds
Convergent:4 milliseconds
Plastic Fiber Optic:2 milliseconds
Glass Fiber Optic (high speed):2 milliseconds
Glass Fiber Optic (high power):15 milliseconds
Glass Fiber Optic (AC-coupled):1 millisecond
Glass Fiber Optic (Emitter & Receiver):2 milliseconds
|
| Repeatability | Opposed:0.01 milliseconds
Non-polarized Retroreflective, Polarized Retroreflective and Non-polarized Retroreflective (clear object):0.2 milliseconds
Diffuse (high speed):0.1 milliseconds
Diffuse (high power):1 millisecond
Convergent:0.2 milliseconds
Plastic Fiber Optic:0.1 milliseconds
Glass Fiber Optic (high speed):0.1 milliseconds
Glass Fiber Optic (high power):1 millisecond
Glass Fiber Optic (AC-coupled):0.01 millisecond
Glass Fiber Optic (Emitter & Receiver):0.01 milliseconds
|
| Delay at Power-up | 200 milliseconds; outputs do not conduct during this time.
|
| Adjustments | OMNI-BEAM sensor heads are field-programmable for four operating parameters. A set of four programming
DIP switches is located at the base of the sensor head and is accessible with the sensor head removed from the
power block
Switch #1:selects the amount of sensing hysteresis
Switch #2:selects the alarm output configurations
Switch #3:selects light operate (switch #3 OFF) or dark operate (switch #3 ON)
Switch #4:selects the STANDARD (switch #4 OFF) or Fine (switch #4 ON) scale factor for the Display And Trouble Alert (D.A.T.A.) light signal strength indicator array
Sensitivity:15-turn slotted brass screw sensitivity (Gain) adjustment potentiometer (clutched at both ends of travel).
|
| Indicators | Sense and Load indictor LEDs are locted on the top of the sensor head on either side of the D.A.T.A array.
Sense LED:indicates when a target has been sensed
Load LED:lights whenever the load (sensor output is energized)
Display And Trouble Alert (D.A.T.A):self-diagnostic system located on the top of the sensor head warns of marginal sensing conditions usually before a sensing failure occurs (except on model OSBFAC)
|
| Construction | Sensor heads are molded of rugged thermoplastic polyester; top view window is polycarbonate; acrylic lenses; stainless-steel hardware.
|
| Environmental Rating | Meets NEMA standards 1, 2, 3, 3S, 4, 12 and 13; IEC IP66 when assembled to power block
|
| Operating Conditions | Temperture:-40° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
|