| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ 45 mA max. (exclusive of load)
|
| Range | Range varies by sensing mode and fiber optics used
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltage
|
| Output Configuration | NPN (current sinking) or PNP (current sourcing), depending on model
Load output:normally open (NO) and programmable light or dark operate
Alarm output:normally open (NO)
|
| Output Rating | 150 mA max. each output; total load may not exceed 150 mA
OFF-state leakage current:less than 10 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
|
| Output Protection Circuitry | Protected against false pulse on power-up; short-circuit protected (trips @ 175 mA)
|
| Output Response Time | 200 microseconds ON/OFF (40 milliseconds OFF when OFF-delay selected)
|
| Delay at Power-up | 0.1 second; outputs do not conduct during this time.
|
| Output Operation Mode | Light operate or dark operate; selected by push button
|
| Output Timing Function | ON/OFF (no delay) or fixed 40 millisecond OFF-delay; selected by push button
|
| Repeatability | 60 microseconds
|
| Adjustments | Push-button TEACH-mode sensitivity setting; Remote TEACH input is provided
|
| Indicators | 2 LED Indicators:Green and Yellow
Green ON steady:power ON
Green flashing:ready for TEACH mode; 1 Hz when ready to learn first condition; 2 Hz for second condition
Yellow ON steady:lights for load output ON (conducting)
7-segment Red bargraph:lights to indicate relative received light signal strength, output program settings, relative contrast level and alarm
|
| Mounting Bracket | D12 Sensors mount directly to a standard DIN rail, or may be through-hole mounted using the supplied mounting bracket and M3 x 0.5 hardware
|
| Construction | Black ABS housing with acrylic cover, stainless-steel M3 x 0.5 hardware for use with thermoplastic polyester mounting bracket (supplied); the plastic fiber clamping element is Acetal
|
| Environmental Rating | IEC IP66; NEMA 4
|
| Connections | PVC-jacketed 2 m or 9 m attached cables
|
| Operating Conditions | Temperature:-20° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
|