| Power Requirements | 16 to 30V dc @ 1.0 A (typical: 0.5 A @ 16V dc)
|
| Inputs | Sensor input:Emitter and receiver wire in parallel to five terminals
Trigger (Gate) input:Optically isolated, requires 10 to 30V dc (7.5 kohms impedance) for alignment sequence signal
Remote alignment input:Optically isolated, requires 10 to 30V dc (7.5 kohms impedance) for alignment sequence signal
|
| Output Configuration | MAHCVN-1:Two NPN (current sinking) discrete outputs, two 0-10V analog voltage sourcing outputs
MAHCVP-1:Two PNP (current sourcing) discrete outputs, two 0-10V analog voltage sourcing outputs
MAHCIN-1:Two NPN (current sinking) discrete outputs, two 4-20 mA analog current sinking outputs
MAHCIP-1:Two NPN (current sinking) discrete outputs, two 4-20 mA analog current sinking outputs
|
| Output Rating | NPN and PNP outputs:150 mA max. @ 30V dc max.
OFF-state leakage current:less than 10 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 150 mA
0-10V dc analog sourcing outputs:25 mA
4-20 mA analog current sinking outputs:16 to 30V dc input
|
| Sensing Performance | Analog resolution:Span/Number of sensing channels
Analog temperature variation:0.01% of full scale/° C
Analog linearity:0.1% of full scale
|
| Serial Data Outputs | RS-232 or RS-485 interface. Up to 15 control modules may be given unique addresses on one RS-485 party line.
ASCII or binary data format
Baud rate:9600, 19.2K or 38.4K, 8 data bits, stop bit, and even, odd or no parity.
|
| Programming | Use RS-232 PC-compatible computer running Window 95, 98, NT, ME, XP or 2000 operating system and Banner supplied software
|
| Indicators | Output 1:
Red ON steady:indicates discrete output #1 is active
ALARM:
Red ON steady:indicates discrete output #2 is active
GATE:
Red ON steady:indicates voltage is applied to Trigger (GATE) input
ALIGN:
Green ON steady:indicates sensor is aligned
DIAG1, 2, 3:identifies system errors and status (see key on side of controller label)
|
| Construction | Polycarbonate
|
| Environmental Rating | IP20; NEMA 1
|
| Operating Conditions | Temperature:0° to +50° C
Relative humidity:95% @ 50° C (non-condensing)
|