| Emitter/Receiver Range | 400 mm to 4 m (16 in. to 13 ft.)
|
| Field of View | Nominally ±3°
|
| Beam Spacing | 5 mm (0.2 in)
|
| Light Source | Infrared LED
|
| Minimum Object Detection Size | Straight Scan, Low-Contrast: 5 mm (0.2 in)
Straight Scan, High-Excess-Gain: 10 mm (0.4 in)
See Figure 2-5 for other scan mode values; size is tested
using a rod.
|
| Sensor Positional Resolution | Straight Scan: 5 mm (0.2 in)
Double-Edge Scan: 2.5 mm (0.1 in)
Single-Edge Scan: 2.5 mm (0.1 in)
|
| Supply Voltage (Limit Values) | Emitter: 12 to 30V dc
Receiver Models: 18 to 30V dc
|
| Supply Power Requirements | Emitter/Receiver Pair (Exclusive of Discrete Load):
Less than 9 watts
Power-up delay: 2 seconds
|
| Teach Input (Receiver Gray Wire) | Low: 0 to 2 volts
High: 6 to 30 volts or open (input impedance 22 K ohms)
|
| Two Discrete Outputs | Protected against false pulse on power-up and continuous
overload or short circuit.
Discrete Output 1 (SIO Mode)
Type: Solid-State Push-Pull
Rating: 100 mA maximum (sourcing or sinking)
ON-State Saturation Voltage: less than 3V @ 100 mA
(sourcing or sinking)
Discrete Output 2
Type: Solid-State NPN or PNP (current sinking or
sourcing)
Rating: 100 mA maximum
OFF-State Leakage Current: NPN: less than 200 uA
@ 30V dc; PNP: less than 10 uA @ 30V dc
ON-State Saturation Voltage: NPN: less than 1.6V @
100 mA; PNP: less than 2.0V @ 100 mA
|
| Two Analog Outputs | Voltage Sourcing: 0 to 10V (maximum current load of 5 mA)
|
| IO-Link Communication Interface | Baud Rate: 230, 400 bps
Parity: Even
Stop Bit: 1
Process Data Width: 16 bits
|
| Scan Time | Scan times depend on scan mode and sensor length.
Straight scan times range from 2.8 to 26.5 ms. See
Figure 2-8 for all combinations.
|
| System Configuration (Receiver Interface) | 6-position DIP switch: Used to set scanning type,
measurement modes, analog slope, and discrete output
2 function (see Configuration DIP Switch on page
27 of IO-Link Instruction Manual)
Push Buttons: Two momentary push buttons for alignment
and gain level selection
|
| System Configuration (IO-Link Interface) | Supplied IODD files provide all configuration options of
receiver interface, plus additional functionality; see
Overview on page 5 of Instruction Manual and IODD (IO-Link Device Description)
on page 33
|
| Status Indicators | See Status Indicators on page 7 of Instruction Manual
|
| Connections | Communication Interface: The receiver uses a cable
splitter that converts the 8-pin connector to a compatible
M12 IO-Link connector; see Cordsets and Connections
on page 17 of Instruction Manual.
Other Sensor connections: 8-conductor quick-disconnect
cables (one each for emitter and receiver), ordered
separately; see Cordsets and Connections on
page 17 for available lengths (may not exceed 75 meters long), PVC-jacketed cables measure 5.8 mm diameter, have shield wire; 22-gauge conductors.
|
| Construction | Aluminum housing with clear-anodized finish
Acrylic lens cover
|
| Environmental Rating | IEC IP65
|
| Operating Conditions | Temperature: -40° to +70° C (-40° to +158° F)
Maximum relative humidity: 95% at 50° C (non-condensing)
|
| Certifications | CE; IO-Link
|