| Supply Voltage and Current | 85 to 264V ac, 50/60 Hz or 48 to 250V dc (1.5 W max. exclusive of load)
|
| Range | 200 mm to 8 m
|
| Ultrasonic Frequency | 75 kHz
Rep. rate:96 milliseconds
|
| Supply Protection Circuitry | Protected against transient overvoltages
|
| Output Configuration | SPDT (Single-Pole, Double Throw) electromechanical relay output. One normally open (NO) and one normally closed (NC)
|
| Output Rating | Max. switching power (resistive load):2000 VA, 240 W (1000 VA, 120 W for sensors with Micro-style QD)
Max. switching voltage (resistive load):250V ac, 125V dc
Max. switching current (resistive load):8 A @ 250V ac, 8 A @ 30V dc derated to 200 mA @ 125V dc (4 A max. for sensors with Micro-style QD)
Min. voltage and current:5V dc, 10 mA
Mechanical life of relay:50,000,000 operations
Electrical life of relay at full resistive load:100,000 operations
Note:Transient suppression is recommended when switching inductive loads.
|
| Output Protection | Protected against short circuit conditions
|
| Output Response Time | Selectable 1600, 400 or 100 milliseconds
|
| Delay at Power-up | 1.5 seconds
|
| Temperature Effect | Uncompensated:0.2% of distance/° C
Compensated:0.02% of distance/° C
|
| Repeatability | 1.0 mm
|
| Hysteresis | Window limit sensor models:5 mm
Fill-level control sensor models:0 mm
|
| Minimum Window Size | 20 mm
|
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons.
Sensor Configuration:Output response time and temperature compensation mode may be set using the Speed push button.
Factory default settings: 400 milliseconds output response time and temperature compensation enabled
|
| Indicators | Green Power ON LED:indicates power is ON
Red Signal LED:indicates target is within sensing range, and the condition of the received signal
TEACH/Output indicator (bicolor Yellow/Red):indicates output status or TEACH mode
Response indicator (bicolor Yellow/Red:indicates output response time selection
|
| Construction | Transducer:ceramic/epoxy composite
Housing:ABS
Membrane switch:polyester
|
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P
|
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Micro- or Mini-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-20° to +70° C
Relative humidity:100%
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
|
| Temperature Warmup Drift | Less than 1.0% of sensing distance upon power-up with Temperature Compensation enabled
|
| Application Note | Objects passing inside the specified near limit (200 mm) may produce a false response.
|