| Supply Voltage and Current | Fixed-field (DC):10 to 30V dc (10% max. ripple) @ less than 40 mA (exclusive of load)
Fixed-field (AC/DC):24 to 250V ac, 50/60 Hz or 12 to 250V dc (1.0 watt max.)
Adjustable-field:10 to 30V dc (10% max. ripple within specified limits) at < 80 mA at 10V dc; < 40 mA at 30V dc
|
| Range | Fixed-field:200, 400 or 600 mm cutoff, depending on model
Adjustable-field:adjustable between 50-600 mm
|
| Supply Protection Circuitry | Protected against reverse polarity, over voltage and transient voltages
|
| Output Configuration | DC models:
Bipolar: One NPN (current sinking) and one PNP (current sourcing); light operate (LO) or dark operate (DO) selectable or configurable, depending on model
AC/DC models:SPDT (Single-Pole Double-Throw) electromechanical relay output
|
| Output Rating | Fixed-field (DC):
- 100 mA max. each output @ 25° C
- OFF-state leakage (NPN):less than 200 µA @ 30V dc
- OFF-state leakage (PNP):less than 10 µA
- ON-state saturation voltage (NPN):less than 1.6V @ 100 mA
- ON-state saturation voltage (PNP):less than 2.0V @ 100 mA
Fixed-field (AC/DC):
- Max. switching power (resistive load):150 W, 1250 VA
- Max. switching voltage (resistive load):250V ac; 125V dc
- Max. switching current (resistive load):5 A @ 250V ac; 5 A @ 30V dc derated to 200 mA @ 125V dc
- Min. voltage and current:5V dc, 10 mA
- Mechanical life of relay:50 million operations
- Electrical life of relay at full resistive load:100,000 operations
Adjustable-field:
- 100 mA max. load (derate approximately 1 mA/° C above 30° C)
- OFF-stage leakage current:less than 5 µA @ 30V dc
- ON-stage saturation voltage (NPN):less than 1.5V @ 100 mA
- ON-state saturation voltage (PNP):less than 2.0V @ 100 mA
|
| Output Protection Circuitry | DC models:Protected against output short-circuit, continuous overload, transient over-voltages and false pulse on power-up
|
| Output Response Time | Fixed-field (DC):2 milliseconds ON/OFF; 100 ms delay on power-up; outputs do not conduct during this time
Fixed-field (AC/DC):15 milliseconds ON/OFF; 100 ms delay on power-up; outputs do not conduct during this time
Adjustable-field: 5 millisecond ON/OFF; 200 ms delay on power-up; outputs do not conduct during this time
|
| Repeatability | Fixed-field (DC):500 microseconds
Adjustable-field:750 microseconds
|
| Adjustments | Fixed-field (DC):
Light operate:High (open or 5 to 30V)*
Dark operate: Low (0 to 3V)*
Adjustable-field: Four-turn adjustment screw sets cutoff distance between min. and max. positions, clutched at both ends of travel
|
| Indicators | Large, oval LED indicator on back:
* Yellow ON steady: output conducting
2 LED indicator on top: Green and Yellow
* Green ON steady: power ON
* Yellow ON steady: light sensed
* Yellow flashing:marginal excess gain (1.0-1.5x excess gain)
Adjustable-field:
2 Indicator LEDs on sensor top:
* Green ON steady: Power ON
* Yellow ON steady: Light sensed (excess gain > 1.5x)
* Yellow flashing: Marginal sensing condition (excess gain < 1.5x)
2 Indicator LEDs on sensor back:
* Small Blue/Red End-of-travel (EOT) LED
* Large Yellow Output LED
|
| Construction | Fixed Field:
PC/ABS housing with acrylic lens cover
Adjustable-field:
ABS housing, acrylic lens cover; 2.5 mm and 3 mm mounting hardware included
QD models: nickel-plated brass
|
| Environmental Rating | IP67; NEMA 6
|
| Connections | DC models:5-conductor 2 m or 9 m attached PVC cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
AC/DC models:2 m or 9 m 5-wire PVC cable
Adjustable-field: 2 m (6.5') 5-wire PVC cable, 9 m (30') PVC cable, or 5-pin Integral QD or Euro-style 150 mm (6 in.) pigtail QD, depending on model
|
| Operating Conditions | Fixed-field:
Temperature:-20 to +70° C
Relative humidity:90% @ 50° C (non-condensing)
Adjustable-field:
Temp: –20° to +60° C (–4° to 140° F)
Relative Humidity: 95% @ 50° C (non-condensing)
|
| Vibration and Mechanical Shock | DC models:All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz max., double amplitude 0.06-inch acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
|
| Certifications | Adjustable-field: CE
AC/DC: UL, cULus Listed
|