| Supply Voltage and Current | 12 to 24V dc (10% max. ripple); 108 mA max. @ 24V dc or [2600/V dc] mA
|
| Sensing Range | Diffuse:
90% white card:0.3 to 5 m
18% gray card:0.3 to 3 m
6% black card:0.3 to 2 m
Retroreflective:0.5 to 50 m, range is specified using one model BRT-TVHG-8x10P retroreflector
|
| Sensing Beam | Typical beam dia.:6 mm @ 3 m
Typical laser lifetime:75,000 hours
Diffuse:658 nm visible red IEC and CDRH Class 2 laser; 0.5 mW max. radiant output power
Retroreflective:658 nm visible red IEC and CDRH Class 1 laser; 0.15 mW max. radiant output power
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | Dual NPN (current sinking) or PNP (current sourcing), selectable depending on wiring hookup
|
| Output Rating | 100 mA max.
OFF-state leakage current:less than 5 µA
Output saturation:
NPN:less than 200 mV @ 10 mA; less than 600 mV @ 100 mA
PNP:less than 1.2V @ 10 mA; less than 1.6V @ 100 mA
|
| Output Protection Circuitry | Protected against short circuit conditions
|
| Output Response Time | Fast:1 millisecond ON/OFF
Medium:10 milliseconds ON/OFF
Slow:100 milliseconds ON/OFF
|
| Delay at Power-up | 1 second; outputs do not conduct during this time.
|
| Color Sensitivity | Diffuse:
90% white to 18% gray:less than 10 mm
90% white to 6% black:less than 20 mm
|
| Discrete Output Hysteresis | Diffuse:
Fast:10 mm
Medium:5 mm
Slow:3 mm
Retroreflective:
Fast:20 mm
Medium:10 mm
Slow:6 mm
|
| Temperature Effect | Diffuse:less than 2 mm/° C
Retroreflective:less than 3 mm/° C
|
| Minimum Window Size | Diffuse:20 mm
Retroreflective:40 mm
|
| Remote TEACH Input | 18 k ohms (65 k ohms @ 5V dc)
|
| Remote TEACH | To TEACH:connect yellow wire to +5 to 24V dc
To disable:connect yellow wire to 0 to +2V dc (or open connection)
|
| Adjustments | Response speed:Push button toggles between fast, medium and slow (see Output Response Time)
Window limits (analog or discrete):TEACH-mode programming of near and far window limits. Limits may also be taught remotely using TEACH input.
|
| Laser Control | Connect red wire to +5 to 24V dc to enable laser beam; connect to 0 to +1.8V dc (or open connection) to disable; when sensor is powered laser enable time is 100 millisecond delay on enable, when sensor is powered.
|
| Indicators | Green Power ON LED:indicates when power is ON, overloaded output and laser status
Yellow Output LED:indicates when discrete load output is conducting
Red Signal LED:indicates target is within sensing range and the condition of the received light signal
Yellow Speed LED:indicates the response speed setting
Red/Yellow TEACH LEDs:in programming mode; indicate active output(s)
|
| Construction | Housing:ABS/polycarbonate blend
Window:acrylic
Quick-disconnect:ABS/polycarbonate blend
|
| Environmental Rating | IP67; NEMA 6
|
| Connections | 7-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 8-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:0° to +50° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Application Notes | • For best accuracy, allow 30-minute warm-up before programming or operating
• Retroreflective performance specifications are based on use with supplied BRT-TVHG-8X10P high grade target. Results may vary with other retroreflective target materials.
|