| Supply Voltage and Current | 10 to 30V dc (10% maximum ripple within specified limits)
Supply current (exclusive of load current): 75 mA max @ 10V dc 35 mA @ 30V dc
|
| Supply Protection Circuitry | Protected against reverse polarity and transient over voltages
|
| Output Configuration | Single output: one current sourcing (PNP) or one current sinking (NPN) open-collector transistor by model
|
| Output Rating | ON-state load current: 100 mA max
OFF-state leakage current: NPN < 200 microamps;
PNP < 10 microamps (see Application Note 1)
NPN Saturation: < 1.6V at 100 mA
PNP Saturation: < 3.0V at 100 mA
|
| Output Protection Circuitry | Protected against false pulse on power up and continue overload or short-circuit of output
|
| Output Response Time | 50 microseconds
Note: 1 second delay on power-up; output does not
conduct during this time
|
| Repeatability | 15 microseconds
|
| Tri-Color LED Sensing Image | Rectangular: 1.2 mm x 3.8 mm (0.05
|
| Construction: | Housing: Zinc alloy die-cast and steel housing with black painted finish and o-ring sealed lens and lens port cap
Lens: Acrylic
Lens port cap and lens holder: ABS
Push-buttons: Thermoplastic elastomer
Labels: Polycarbonate
|
| Adjustments | MODE Push-button
Selects Operating Mode
TEACH Push-button
Initiate Teach from STATIC or DYNAMIC Mode
Both Push-buttons >2 s
Enter Sensor Set-up (only accessible from RUN Mode)
Remote Input (gray wire)
Input for remote Set-up of the sensor (PLC compatible)
|
| Connections | PVC-jacketed 5 conductor 2 m (6.5') or 9 m (30') cable
with internal strain relief
Integral 5-pin Euro-style QD fitting
150 mm (6
|
| Operating Conditions | Temperature: -10° to -55° C (+14° to 131° F)
Storage Temperature: -20° to +80° C (-4° to 185° F)
Maximum Relative Humidity: 90% at 50° C (non-condensing)
|
| Environmental Rating | IEC IP67
|
| Vibration and Mechanical Shock | All models meet IEC 68-2-6 and IEC 68-2-27 testing criteria
|
| Application Notes | 1. NPN OFF-state leakage current is < 200 µA for load impedances > 3kΩ or optically isolated loads. For load current of 100 mA, leakage is < 1% of load current.
2. Do not mount the sensor directly perpendicular to shiny surfaces; position it at approximately a 15° angle in relation to the sensing target (see Installation Notes).
3. Minimize web or product
|