| Supply Voltage and Current | 10 to 30V dc
Power consumption: approx. 1.8W @ 24V dc (with no output load), for each STB
|
| Supply Protection Circuitry | Protected against transient voltages and reverse polarity
|
| Output Configuration | Complementary PNP (sourcing) open-collector transistors
|
| Output Rating | Maximum load: 150 mA
On-state saturation voltage: ≤ 15V @ full load
Off-state leakage current: < 1 μA
|
| Output Protection Circuitry | Protected against false pulse on power-up; overload and short-circuit protection.
|
| Output Response Time | 20 milliseconds ON/OFF
|
| STB Indicators | 2 green LED indicators:
Power: ON – power applied
Output/fault: ON – button is activated; OFF – button is deactivated; Flashing – internal fault or blocked button on power-up detected
|
| Construction | STB Buttons: Totally encapsulated, non-metallic enclosure; black polyetherimide yoke housing (see Application
Note below); fiber-reinforced polyester base; electronics fully epoxy-encapsulated.
E-Stop Button: Polyamide red button with metal base.
Run Bar Housing: 13 ga (0.090 in.) cold rolled steel with powder coat paint; polypropylene copolymer STB mount.
|
| Environmental Rating | STBVP6-RB1 Run Bar Models meet IP20
STBVP6-RB2 Run Bar Models meet IP65
|
| Connections | Models STBVP6-RB1/-RB2 and -RB1E02/-RB2E02: Terminal strip connections inside run bar housing (STBs are pre-wired). E-stop button and EZ-LIGHT indicator (if used) are wired separately.
Models STBVP6-RB1Q8/-RB2Q8: 8-pin Mini-style quick-disconnect fitting
|
| Ambient Light Immunity | Up to 100,000 lux
|
| EMI/RFI Immunity | Immune to EMI and RFI noise sources, per IEC 947-5-2.
|
| Operating Conditions | Temperature: 0º to +50º C (+32º to +122º F)
Maximum relative humidity: 90% @ +50º C (non-condensing)
|
| Application Notes | The STB’s polyetherimide upper housing will become brittle with prolonged exposure to outdoor sunlight.
Window glass effectively filters longer wavelength ultraviolet light and provides excellent protection from sunlight.
Avoid contact with strong alkalis, hydrocarbons and fuels. Clean periodically using mild soap solution and a soft
cloth. (Polycarbonate STB models are also available for use with the Run Bar; contact Factory for assistance.)
|
| Certifications | STB Buttons: CE, cULus listed
STBVP6-RB2...Run Bars: CE
|