| Range | The sensor is able to detect a proper retroreflective target (see below) up to 12 meters, depending on target.
|
| Detectable Objects | Objects containing metal, water, or similar high-dielectric materials.
|
| Operating Principle | Frequency modulated continuous-wave (FMCW) radar
|
| Operating Frequency | 24.00 to 24.25 GHz, ISM Band (varies slightly with model, depending on national telecom regulations)
|
| Supply Voltage | 12 to 30V dc, less than 100 mA, exclusive of load
|
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages
|
| Delay at Power-up | Less than 2 seconds
|
| Output Configuration | Bipolar NPN/PNP output, 150mA; DIP switch 7 selects N.O. (default) or N.C. operation
|
| Output Protection | Protected against short circuit conditions
|
| Indicators | Power LED:Green (power ON)
Signal Strength LED:Red, flashes in proportion to signal strength. Steady on at 4x the sensitivity adjusted baseline (indicating 4x excess gain). Only indicates signal amplitude, not target distance.
Output LEDs:Yellow (output energized)/Red configuration)
|
| Response Time | DIP-switch 8 selects ON/OFF response time
|
| Adjustments | DIP-switch-configurable sensitivity and output configuration; remote line teach of the retroreflective target
|
| Construction | Housing:ABS/polycarbonate
Lightpipes:Acrylic
Access Cap:Polyester
|
| Operating Temperature | –40° to +65° C (–40° to +149° F)
|
| Environmental Rating | IP67
|
| Connections | Integral 5-wire 2 m (6.5') cable or M12 Euro-style QD fitting. QD models require a mating cordset
|
| Certifications | CE and ETSI/EN 300 440; FCC part 15; Industry Canada; for others, consult the Factory.
|