| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ less than 1 W each for emitter and receiver (exclusive of load)
|
| Range | Short-range models:
Normal range (see hookups):100 to 200 mm
Reduced range:75 to 150 mm
Standard-range models:
Normal range (see hookups):300 mm to 2 m
Reduced range:150 to 600 mm
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing)
|
| Output Rating | 150 mA max. each output
OFF-state leakage current:less than 5 µA
Output saturation voltage:
PNP:less than 1V @ 10 mA; less than 1.5V @ 100 mA
NPN:less than 1.5V @ 10 mA; less than 0.6V @ 100 mA
|
| Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short circuit of outputs
|
| Output Response Time | LX3:0.8 milliseconds ON-time; 6 milliseconds OFF-time (5 milliseconds OFF-delay)
LX6:1.6 milliseconds ON-time; 7 milliseconds OFF-time (5 milliseconds OFF-delay)
LX12:3.2 milliseconds ON-time; 8.5 milliseconds OFF-time (5 milliseconds OFF-delay)
|
| Minimum Object Detection Size | Smallest diameter rod that can be detected in sensing range: 5.6 mm (short range) or 9.5 mm (standard-range), depending on model.
|
| Indicators | Emitter, 2 LED indicators:Green and Red
Green ON steady:power ON
Green OFF:emitter hardware failure
Red ON steady:reduced range
Red OFF:normal range
Red flashing:emitter hardware failure
Receiver, 2 LED indictors:Yellow and bicolor green/red
Yellow ON steady:output conducting
Yellow OFF:output not conducting
Green ON steady:normal range
Red ON steady:reduced range
Red flashing:receiver hardware failure
|
| Construction | Aluminum housing, polystyrene plastic endcaps, acrylic lens window
|
| Environmental Rating | IEC IP65
|
| Connections | 5-conductor (with drain) attached PVC cable or 150 mm pigtail with 5-pin Euro-style quick-disconnect fitting, depending on model. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-20° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Application Notes | i) The best sensing resolution occurs within the center 80 percent of the sensing area, between the emitter and receiver.
ii) Low-profile packages can be reliably detected.
iii) Outputs are energized whenever the light screen is interrupted.
iv) Successive parts musts be spaced up to 12 milliseconds (LX12) for reliable detection.
|