| Supply Voltage | 5 to 15V dc (provided by the amplifier to which the sensor is connected)
|
| Range | Opposed:6 m
Non-polarized Retroreflective:5 m, range is specified using one model BRT-3 retroreflector
Polarized Retroreflective:50 mm to 2 m, range is specified using one model BRT-3 retroreflector
Diffuse:380 mm
Divergent Diffuse:75 mm
Convergent:16 or 43 mm, depending on model
Glass Fiber Optic:Range varies by sensing mode and fiber optics used
|
| Output | Constant current output:1 mA or less in the dark condition and 2.1 mA or less in the light condition
|
| Output Response Time | Opposed Receiver:2 milliseconds ON; 400 microseconds OFF
All others:5 milliseconds ON/OFF (does not include amplifier response)
|
| Ajustments | 15-turn slotted brass screw sensitivity (Gain) adjustment potentiometer, clutched at both ends of travel; located on rear panel of sensor and protected by a gasketed, clear acrylic cover.
|
| Indicators | Alignment Indicating Device system (AID) lights a rear-panel mounted red LED indicator whenever the sensor sees a light condition, with a superimposed pulse rate proportional to the light signal strength (the stronger the signal, the faster the pulse rate).
|
| Construction | Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses and stainless-steel screws
|
| Environmental Rating | NEMA 1, 2, 3, 3S, 4, 4X, 6, 12 and 13; IEC IP67
|
| Connections | PVC-jacketed 2-conductor 2 m or 9 m cables, or special 4-pin Euro-style QD. QD cable are ordered separately.
|
| Operating Conditions | Temperature:-40° C to + 70° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Design Standards | MIAD9 Series sensors comply with the following standards:
DIN 19 234, EN 50 014 Part 1. 1977, EN50 020 Part 7. 1977, Factory Mutual #3610 and 3611, CSA 22.2 #157-92 and 22.2 #213-M1987
|