| Supply Voltage and Current | DC models:10 to 30V dc (10% max. ripple)
Emitters:25 mA (exclusive of load)
Receivers:20 mA (exclusive of load)
AC models:20 to 250V ac (50/60 Hz)
Average Current:20 mA
Peak current:200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac
|
| Range | 60 m
|
| Supply Protection Circuitry | DC models:Protected against reverse polarity and transient voltages
AC models:Protected against transient voltages
|
| Output Configuration | DC models:
Solid-state complementary (SPDT) dc switch::NPN (current sinking) or PNP (current sourcing), depending on model. The dark operate (DO) output may be wired as a normally open marginal signal alarm output, depending upon hookup to the power supply.
AC models:
SPST solid-state ac switch; three-wire hookup:Light operate (LO) or dark operate (DO), depending on model
Light operate:Output conducts when the sensor sees its own (or the emitter’s) modulated light
Dark operate:Output conducts when the sensor sees its own (or the emitter’s) modulated light
|
| Output Rating | DC models:150 mA max. (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA
OFF-state leakage:less than 1 µA @ 30V dc
ON-state saturation voltage:less than 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
AC models:300 mA max. (continious)
Inrush capability:1 A for 20 milliseconds, non-repetitive
OFF-state leakage current:less than 100 µA
ON-state voltage drop:3V @ 300 mA ac; 2V @ 15 mA ac
|
| Output Protection Circuitry | DC models:Protected against false pulse on power-up and continuous overload or short circuit of outputs
AC models:Protected against false pulse on power-up
|
| Output Response Time | Response time is independent of signal strength.
DC models:3 milliseconds ON; 1.5 milliseconds OFF
AC models:16 milliseconds ON; 8 milliseconds OFF
|
| Delay at Power-up | DC models:100 milliseconds; outputs do not conduct during this time.
AC models:100 milliseconds
|
| Repeatability | Repeatability is independent of signal strength.
DC models:375 microseconds
AC models:2 milliseconds
|
| Indicators | DC models, 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Green flashing:output is overloaded
Yellow ON steady:light-operate (LO) output is energized
Yellow flashing:marginal excess gain (1-1.5x) in light condition, LO output is energized
AC models, 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Yellow ON steady:sensor sees light
Yellow flashing:marginal excess gain (1-1.5x) in light condition
|
| Construction | Thermoplastic polyester housing with polycarbonate or acrylic lenses. Two jam nuts are included with each sensor.
|
| Environmental Rating | Leakproof design rated NEMA 6P; DIN 40050 (IP69K)
|
| Connections | DC models:2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
AC models:2 m or 9 m attached cable, or 4 pin Micro-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-40° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
|