| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ less than 45 mA (exclusive of load)
|
| Range | Varies by sensing mode and fiber optics used
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltage
|
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing)
|
| Output Rating | 150 mA max. load
OFF-state leakage current:less than 5 µA @ 30V dc
ON-state saturation voltage:
NPN:less than 200 mV @ 10 mA; 1V @ 150 mA load
PNP:less than 1V @ 10 mA; 1.5V @ 150 mA load
|
| Output Protection Circuitry | Protected against false pulse on power-up and continuous short-circuit
|
| Output Response Time | 500 microseconds (normal mode) or 200 microseconds (high-speed mode)
|
| Delay at Power-up | 200 millisecond; outputs do not conduct during this time.
|
| Repeatability | 100 microseconds (normal mode) or 66 microseconds (high-speed mode)
|
| Adjustments | Two push buttons and remote wire
Push buttons or remote wire:Expert TEACH programming (two-point static, dynamic and single-point static), light operate (LO)/dark operate (DO), OFF-delay and response speed
Push button only:Manually adjust (+/-) sensitivity
Remote wire only:Push-button lockout
|
| Indicators | 8-segment Red bargraph:Light-to-dark signal difference relative to taught condition (single-point TEACH )
Green status indicators:LO, DO, High Speed and OFF-delay
Green LED:Power ON
Yellow LED:Output conducting
|
| Construction | Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover.
|
| Environmental Rating | NEMA 1; IEC IP50
|
| Connections | PVC-jacketed 2 m or 9 m 6-wire attached cable or integral 6-pin Pico-style QD. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-10° to +55° C
Storage Temperature:-20° to +85° C
Relative humidity:90% @ 50° C
|
| Installation | 35 mm DIN rail or included mounting bracket
|