L-GAGE Q50 Series—Discrete

Product image

Overview

  • 12 to 30V dc supply voltage with NPN or PNP output, depending on model
  • Visible red models with 50 to 150 mm or 100 to 300 mm sensing range
  • Infrared models with 50 to 200 mm or 100 to 400 mm sensing range
  • Push-button TEACH-mode programming for custom sensing windows
  • Remote programming for added security and convenience
  • Output response speed of 4 or 48 milliseconds, depending on model
  • Sensor linearity less than 1 percent of full scale

Product Specifications

Supply Voltage and Current12 to 30V dc (10% max. ripple) @ 70 mA max. (exclusive of load)
Sensing RangeQ50AV models:50 to 150 mm
Q50AN and Q50AP models:50 to 200 mm
Q50BV models:100 to 300 mm
Q50BN and Q40BP models:100 to 400 mm
Sensing BeamWavelength:
Q50AV and Q50BV models:685 nm typical
Q50AN, Q50AP, Q50BN and Q50BP models:880 nm typical
Beam Size:20 mm dia. max.
Supply Protection CircuitryProtected against reverse polarity and transient voltages
Output ConfigurationSolid-state complementary (SPDT):NPN (current sinking) or PNP (current sourcing), depending on model
Output Rating150 mA max. each output OFF-state leakage current:less than 10 µA
ON-State saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 100 mA
Output Protection CircuitryProtected against false pulse on power-up and continuos overload or short circuit of outputs
Output Response TimeFast:4 milliseconds ON/OFF
Slow:48 milliseconds ON/OFF
Delay at Power-up2 seconds
Sensing Repeatability4 millisecond response time models:1.0% of sensing distance
48 millisecond response time models:0.5% of sensing distance
Remote TEACH and Speed Input Impedance15 k ohms
Remote TEACH InputTo TEACH:connect gray wire to +5 to 30V dc
To disable:connect gray wire to 0 to +2V dc (or open connection)
AdjustmentsSensing window limits:TEACH-mode programming of near and far window limits may be set using the TEACH push button or remotely using the gray TEACH wire.
IndicatorsRange LED indicator:Green/Red
Green ON steady:target is within sensing range
Red ON steady:target is outside sensing range
Green flashing:outputs are overloaded
OFF:sensor power OFF
TEACH/Output LED indicator:Yellow/Red
Yellow (window limits):target is within taught window limits
Yellow (fixed field):target is closer than cutoff limit
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
Minimum Taught WindowQ50BVN and Q50AVP models:
Target distance @ 100 mm:1 mm window
Target distance @ 150 mm:2.0 mm window
Target distance @ 200 mm:3.5 mm window
Target distance @ 250 mm:5.0 mm window
Target distance @ 300 mm:7 mm window
Q50BVN..Y and Q50BVP..Y models:
Target distance @ 100 mm:2 mm window
Target distance @ 150 mm:4 mm window
Target distance @ 200 mm:7 mm window
Target distance @ 250 mm:10 mm window
Target distance @ 300 mm:14 mm window
Q50BN and Q50BP models:
Target distance @ 100 mm:1 mm window
Target distance @ 150 mm:2.0 mm window
Target distance @ 200 mm:3.5 mm window
Target distance @ 250 mm:5.0 mm window
Target distance @ 300 mm:7 mm window
Target distance @ 350 mm:10 mm window
Target distance @ 400 mm:15 mm window
Q50BN..Y and Q50BP..Y models:
Target distance @ 100 mm:2.0 mm window
Target distance @ 150 mm:4 mm window
Target distance @ 200 mm:7 mm window
Target distance @ 250 mm:10 mm window
Target distance @ 300 mm:14 mm window
Target distance @ 350 mm:20 mm window
Target distance @ 400 mm:30 mm window
Q50AVN and Q50AVP models:
Target distance @ 50 mm:1 mm window
Target distance @ 75 mm:1.5 mm window
Target distance @ 100 mm:2 mm window
Target distance @ 125 mm:4 mm window
Target distance @ 150 mm:5 mm window
Q50AVN..Y and Q50AVP..Y models:
Target distance @ 50 mm:2 mm window
Target distance @ 75 mm:3 mm window
Target distance @ 100 mm:4 mm window
Target distance @ 125 mm:7 mm window
Target distance @ 150 mm:9 mm window
Q50AN and Q50AP models:
Target distance @ 50 mm:1 mm window
Target distance @ 75 mm:1.5 mm window
Target distance @ 100 mm:2 mm window
Target distance @ 125 mm:4 mm window
Target distance @ 150 mm:5 mm window
Target distance @ 175 mm:6 mm window
Target distance @ 200 mm:7 mm window
Q50AN..Y and Q50AP..Y:
Target distance @ 50 mm:2 mm window
Target distance @ 75 mm:3 mm window
Target distance @ 100 mm:4 mm window
Target distance @ 125 mm:7 mm window
Target distance @ 150 mm:9 mm window
Target distance @ 175 mm:12 mm window
Target distance @ 200 mm:15 mm window
Ambient Light Immunityless than 10,000 lux.
ConstructionHousing:molded ABS/Polycarbonate
Window lens:acrylic
Environmental RatingIEC IP67; NEMA 6P
Connections5-conductor 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
Operating ConditionsTemperature:-10° to +55° C
Relative humidity:90% @ 50° C (non-condensing)
Vibration and Mechanical ShockAll models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
Application NoteAll 15-minute warm-up for maximum performance

English

Data Sheets

Document Name Part Number File Size Download
1. L-GAGE Q50 Series, Discrete Outputs
(Long Range)
65741 654K Download
2. L-GAGE Q50 Series, Discrete Outputs
(Short Range)
67417 309K Download

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

"No more costly wiring runs"

“I’m delighted with Banner’s SureCross wireless system. It gives us comprehensive monitoring and control in previously inaccessible locations. And it’s easy to expand and relocate as needed.”

Worldwide Distributors

Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code


Find international distributors