| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ 40 mA max. (exclusive of load)
|
| Range | 200 mm to 8 m
|
| Ultrasonic Frequency | 75 kHz
Rep. rate:96 milliseconds
|
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages
|
| Output Configuration | Voltage sourcing:0-10V dc
Current sourcing:4-20 mA
|
| Output Rating | 0-10V dc models:
Minimum load resistance:500 ohms
Minimum required supply voltage for full 0-10V output span:[(1000/RLOAD)+13]V dc
4-20 mA models:
Maximum load resistance:1 k ohms or [(V supply/0.02) - 5] ohms, whichever is lower
Minimum required supply voltage for full 4-20 mA output span:10V dc or [(RLOAD x 0.02) + 5]V dc, 4-20 mA output calibrated at 25° C with a 250 ohms load.
|
| Output Protection | Protected against short circuit conditions
|
| Output Response Time | 100 to 2300 milliseconds
|
| Delay at Power-up | 1.5 seconds
|
| Temperature Effect | Uncompensated:0.2% of distance/° C
Compensated:0.02% of distance/° C
|
| Linnearity | +/- 0.2% of span from 200 to 8000 mm; +/- 0.1% of span from 500 to 8000 mm (1 mm minimum)
|
| Repeatability | 1.0 mm
|
| Minimum Window Size | 20 mm
|
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons or remotely using TEACH input.
|
| Indicators | Green Power ON LED:indicates power is ON
Red Signal LED:indicates target is within sensing range, and the condition of the received signal
TEACH/Output indicator (bicolor Yellow/Red):
Yellow:target is within taught limits
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
|
| Remote TEACH | To TEACH:connect gray or yellow wire to 0 to +2V dc; impedance 12 k ohms
|
| Construction | Transducer:ceramic/epoxy composite
Housing:ABS/Polycarbonate
Membrane switch:polyester
Lightpipes:acrylic
|
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P
|
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro- or Mini-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-20° to +70° C
Relative humidity:100%
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
|
| Temperature Warmup Drift | Less than 0.8% of sensing distance upon power-up with Temperature Compensation enabled
|
| Application Note | Objects passing inside the specified near limit (200 mm) may produce a false response.
|