| Sensing Range | Models ending in A:100 mm to 1 m (3.9 in. to 39 in.)
Models ending in B:200 mm to 2 m (7.8 in. to 78 in.)
Models ending in C:300 mm to 3 m (11.8 in. to 118 in.)
|
| Ultrasonic Frequency | Models ending in A:224 kHz
Models ending in B:174 kHz
Models ending in C:114 kHz
|
| Supply Voltage | 10 to 30V dc (10% max. ripple) at 40 mA, exclusive of load
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | Analog Output: 0 to 10V dc or 4 to 20 mA, depending on model
|
| Output Rating | Analog Voltage Output:2.5 kΩ min. load resistance Minimum supply for a full 10V output is 12V dc (for supply voltages between 10 and 12, V out max. is at least V supply -2)
Analog Current Output:1 kΩ max. @ 24V input; max. load resistance = (Vcc-4)/0.02Ω
For current output (4-20 mA) models:ideal results are achieved when the total load resistance R = [(Vin – 4)/0.020]Ω. Example, at Vin = 24V dc, R ≈ 1 kΩ (1 watt)
|
| Output Protection Circuitry | Protected against short circuit conditions
|
| Output Response Time | Models ending in A:45 ms (fast); 105 ms (slow)
Models ending in B:92 ms (fast); 222 ms (slow)
Models ending in C:135 ms (fast); 318 ms (slow)
|
| Delay at Power-up | 500 ms
|
| Temperature Effect | 0.02% of distance/ºC
|
| Linearity | 0.25% of distance
|
| Resolution | Models ending in A:0.1% of distance (0.5 mm min.)
Models ending in B:0.1% of distance (1.0 mm min.)
Models ending in C:0.1% of distance (1.5 mm min.)
|
| Sensing Hysteresis | Models ending in A:2 mm
Models ending in B:3 mm
Models ending in C:4 mm
|
| Minimum Window Size | 10 mm (0.4 in.)
|
| Adjustments | Sensing window limits:TEACH-Mode configuration of near and far window limits may be set using the push button or remotely via TEACH input
Response speed selection:Fast or Slow
Advanced configuration options:Analog output slope, push button enabled/disabled, temperature compensation enabled/disabled
|
| Loss of Signal Indication | 0 to 10V dc models:Analog output goes to 0V
4 to 20 mA models:Analog output goes to 3.6 mA
|
| Construction | Housing:PBT polyester
Push buttons:polyester
Transducer:epoxy /ceramic composite
|
| Environmental rating | Leakproof design, rated IEC IP67 (NEMA 6)
|
| Connections | 2 m (6.5 ft.) or 9 m (30 ft.) shielded 4-conductor (with drain) PVC cable, 150 mm (6 in.) PUR Euro-style pigtail (QPMA), or 4-pin integral Euro-style connector (Q8)
|
| Operating Conditions | Temperature:−40 to 70º C (−40 to +158º F)
Max. Relative Humidity:95% at 50ºC non-condensing
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements method 201A (vibration: 10 to 60 Hz max., double amplitude 0.06 in., max acceleration 10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave
|
| Application Note | The temperature warmup drift upon power-up is less than 1% of the sensing distance.
|
| Certifications | CE Pending
|