| Supply Voltage and Current | 18 to 30V dc (10% maximum ripple); 250 mA max @24V dc (exclusive of load)
|
| Supply Protection Circuitry | Protected against reverse polarity and transient over voltages
|
| Delay at Power-up | 1.25 seconds
|
| Sensing Beam | 670 nm (1mW) visible red IEC and CDRH Class 2 laser
|
| Measuring Frequency | Dynamically adjusted from 300 to 4000 Hz depending on target conditions, or locked via LH Series Configurator software.
|
| Ambient Light | ≤3000 Lux
|
| Output Configuration and Rating | Analog current output:4 to 20 mA (current sourcing)
Analog output rating: 1 kΩ max @ 24V dc, max load resistance = [(Vcc - 4.5)/0.02]Ω
|
| Output Response Time | User adjustable output filtering via LH Series Configurator
software
|
| Temperature Effect | 0.01% of full scale range/°C
|
| Adjustments | None on sensor; Configuration through LH Series Configurator
software
|
| Application Notes | Allow 30-minute warm-up
|
| Construction | Housing:Aluminum
Cover plate: Aluminum
Lens: Glass
Cable: PVC and nickel-plated brass
|
| Environmental Rating | IP67
|
| Connections | 150 mm (6 in.) M12 8-pin Euro-style pigtail quick-disconnect.
Mating QD cables are purchased separately
|
| Serial Communication Interface | RS-485, optically isolated, up to 230 KBaud
|
| Serial Communication Protocol | LH Network
|
| Operating Conditions | Operating Temperature: –10° to +45° C (+14° to 113° F)
Storage Temperature: -10° to 80° C (+14° to 176° F)
Maximum relative humidity: 85% at +45° C, non-condensing
|
| Vibration and Mechanical Shock | Vibration: IEC60947-5-2, 10-55 Hz, 0.5 mm P-P, 3 axis
Shock: IEC60947-5-2, 30G, 11 milliseconds, half sine wave, 3 axis
Maximum mounting bolt tightening torque: 1 Nm
|
| Factory Default Settings | Measurement Mode: Displacement
Sensor Address: Unset (Address 0)
Baud Rate: 115200
Analog Output: 4-20 mA, positive slope, full scale range
|
| Certifications | CE
|