| Supply Voltage and Current | Emitter:10 to 30V dc (10% max. ripple) @ less than 70 mA
Receiver:10 to 30V dc (10% max. ripple) @ less than 22 mA (exlusive of load)
|
| Range | 213 m
|
| Supply Protection Circuitry | Protected against reverse polarity, over voltage and transient voltages
|
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing); light operate (LO) or dark operate (DO) selectable or configurable, depending on model
|
| Output Rating | 100 mA max load
OFF-state leakage:less than 200 µA
ON-state saturation voltage:less than 1.5V @ 100 mA; less than 900 mV @ 10 mA
|
| Output Protection Circuitry | Protected against output short-circuit, continuous overload, transient over-voltages and false pulse on power-up
|
| Output Response Time | 30 milliseconds ON/OFF
|
| Delay at Power-up | 100 milliseconds; outputs do not conduct during this time.
|
| Repeatability | 5 milliseconds
|
| Adjustments | Light operate/dark operate—dependent on model selected
Frequency using gray wire:
A:Gray (+)
B:Gray (-)
LED inhibit (emitter only):White wire (-) turns emitter LED OFF (to allow verification of sensor operation)
|
| Indicators | 4 LED signal stength light bar
Green LED:power ON
Frequency indicator:A or B
Yellow ON steady (receiver only):power ON
|
| Construction | ABS plastic housing; impact-resistant lens material
|
| Environmental Rating | Cabled:IP67; NEMA 6P
QD:IP69K; DIN 40050-9
|
| Connections | 5-conductor 2 m or 9 m attached PVC cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-20 to +60° C
Relative humidity:90% (non-condensing)
|