| Supply Voltage and Current | 10 to 30V dc (10% max. ripple)
Opposed Emitters:25 mA (exclusive of load)
Opposed Receivers:20 mA (exclusive of load)
Polarized Retroreflective:30 mA (exclusive of load)
Fixed-field:35 mA (exclusive of load)
|
| Range | Opposed:60 m
Polarized Retroreflective:6 m, range is specified using one model BRT-3 retroreflector
Fixed-field:0-200, 0-400 or 0-600 mm cutoff, depending on models
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Rating | 150 mA max. (each); the total load may not exceed 150 mA
OFF-state leakage:less than 1 µA @ 30V dc
ON-state saturation voltage:less 1V @ 10 mA dc; less than 1.5V @ 150 mA dc
|
| Output Configuration | Sensing Output:PNP (current sourcing), light operate
Alarm Output:PNP (current sourcing), normally open and conducts whenever the sensor's excess gain drops to 1-1.5x in light condition
|
| Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short-circuit of outputs
|
| Output Response Time | Response time is independent of signal strength
Opposed:3 millisecond ON; 1.5 milliseconds OFF
Polarized Retroreflective and Fixed-field:3 milliseconds ON/OFF
|
| Delay at Power-up | 100 milliseconds; outputs do not conduct during this time.
|
| Repeatability | Repeatability is independent of signal strength
Opposed:375 microseconds
Polarized Retroreflective and Fixed-field:750 microseconds
|
| Indicators | 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Green flashing:output is overloaded
Yellow ON steady:normally open output is conducting
Yellow flashing:marginal excess gain (1-1.5x) in light condition
|
| Construction | Thermoplastic polyester housing with polycarbonate or acrylic lenses. One jam nut is included with each sensor.
|
| Environmental Rating | Leakproof design is rated NEMA 6P; IEC IP67
|
| Connections | 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-40° to +70° C
Relative humidity:90% @ 50° C (non-condensing)
|
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
|