| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ less than 30 mA
|
| Range | Range varies; depending on which receiver is used
|
| Supply Protection Circuitry | Protected against electrostatic discharge (ESD), transient voltages and reverse polarity
|
| Delay at Power-up | M126E1 models:less than 100 milliseconds
M126E2 models:less than 30 milliseconds
|
| Sensing Beam | 650 nm visible red Class 1 or Class 2 laser (temperature coefficient 0.2 nm/°C)
Pulse width:7 microseconds
Rep. rate:30 microseconds
Peak output power:
M126E1 models:0.36 mW
M126E2 models:2.8 mW
|
| Beam Diameter at Aperture | Approx. 2 mm diameter
|
| Beam Divergence | ±0.5 milliradians typical at 25° C; ±1.3 milliradian at operating temperature extremes
|
| Beam Placement | Within 0.25 mm and ±2 milliradians of mechanical centerline axis of housing
|
| Laser Control | Enable beam by applying 10 to 30V dc to black wire; apply 0V dc by opening circuit to inhibit beam
M126E1 models:less than 100 milliseconds
M126E2 models:less than 30 miliseconds
Inhibit delay:less than 1 millisecond
|
| Indicators | 2 LED Indicators visible through rear cover:Green and Yellow
Green ON steady:power ON
Yellow ON steady:laser enabled
|
| Construction | 12.7 mm diameter smooth aluminum barrel; Black hard-coat anodized finish, MIL-A-8625 Type III, Class 2
|
| Environmental Rating | IEC IP67; NEMA 6
|
| Connections | PVC-jacketed 2 m or 9 m high-flex attached cable, or 150 mm pigtail with 3-pin Pico-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:0° to 40° C
Relative humidity:90% @ 40° C (non-condensing)
|
| Laser Classification | M126E1 models:Class 2 (CDRH), US Safety Standards 21 CFR 1040.10; Class 2 (IEC), European Standards EN 60825-1 and IEC 60825-1
M126E2 models:Class 2 (CDRH), US Safety Standards 21 CFR 1040.10; Class 2 (IEC), European Standards EN 60825-1 and IEC 60825-1
|