| Supply Voltage and Current | 12 to 30V dc (10% max. ripple) @ less than 25 mA (exclusive of load) |
|---|---|
| Sensing Range | 50 to 500 mm |
| Ultrasonic Frequency | 300 kHz
Rep. rate:7.5 milliseconds |
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Delay at Power-up | 300 milliseconds |
| Output Configuration | SPST solid-state switch conducts when target is sensed within sensing window; One NPN (current sinking) or one PNP (current soucing), depending on model |
| Output Rating | 100 mA max.
OFF-state leakage current:less than 10 µA (sourcing); less than 200 µA (sinking) NPN saturation:less than 1.6V @ 100 mA PNP saturation:less than 3.0V @ 100 mA |
| Temperature Effect | Non-encapsulated models:±0.05% per ° C from -20° to +50° C, ±0.1% per ° C from +50° to +60° C Encapsulated models:±0.05% per ° C from 0° to +60° C, ±0.1% per ° C from -20° to 0° C |
| Repeatability | 0.7 mm |
| Hysteresis | 1.4 mm |
| Output Response Time | 15 milliseconds |
| Minimum Window Size | 5 mm |
| Adjustments | Sensing window limits:TEACH-mode programming of near and far window limits may be set using the push button or remotely using TEACH input. |
| Indicators | Range Indicator (Red/Green): Green:Target is within sensing range
Red:Target is outside sensing range
OFF:Sensing poser is OFF
Teach/Output Indicator (Yellow/Red):Yellow:Target is within taught limits
Red:Sensor is in TEACH mode
OFF:Target is outside taught window limits
|
| Construction | Sensor housing:ABS Push button:TPE Push-button housing:ABS Lightpipes:Polycarbonate |
| Environmental Rating | IEC IP67; NEMA 6P, or IEC IP68; NEMA 6P depending on model |
| Connections | 2 m or 9 m 4-wire attached PVC cable, or 150 mm pigtail with 4-pin Pico-style QD (Q), or 150 mm pigtail with 4-pin Euro-style QD (Q5), or 4-pin integral Pico-style QD (Q7), or 4-pin integral Euro-style QD (Q8), depending on model. QD cable are ordered separately. |
| Operating Conditions | Temperature:-20° to +60° C Relative humidity:100% (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 milliseconds duration, half sine. |
| Application Note | Objects passing inside the specified near limit may produce a false response. |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | Wave Guide Accessory (UWG18-..) |
130153 | 268K | Download Email |
| 2. | WORLD-BEAM QS18U Ultrasonic Series | 119287 | 993K | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | Ultrasonic Solutions Flyer | 142025 | 1.7MB | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | QS18U Ultrasonic Series - French | FD166 | 1.2MB | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | QS18U Ultrasonic Series - German | GD166 | 1.2MB | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | QS18U Ultrasonic Series - Italian | ID166 | 1.2MB | Download Email |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »The source for all Banner product lines. Features multiple navigation options, applications and product comparisons, and detailed specifications for brackets, cordsets and other accessories.
Get it Now »Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code