| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ less than 25 mA (exclusive of load)
|
| Range | Opposed (long range):Optimum up to 600 mm, 1.2 m max.
Opposed (short range):3.0 m
Convergent:15 or 30 mm, depending on model
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | SPST solid-state switch:NPN (current sinking) or PNP (current sourcing), depending on model. Light operate (LO) or dark operate (DO), depending on model
|
| Output Rating | 50 mA max.
OFF-state leakage current:less than 1 µA @ 24V dc
ON-state saturation voltage:less than 0.25V @ 10 mA dc; less than 0.5V @ 50 mA dc
|
| Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short circuit of outputs; Overload trip point greater than or equal to 100 mA
|
| Output Response Time | Opposed:1 millisecond ON; 0.5 millisecond OFF
Convergent:1 millisecond ON/OFF
|
| Delay at Power-up | Opposed:100 milliseconds max.; outputs do not conduct during this time.
Convergent:150 milliseconds max.; outputs do not conduct during this time.
|
| Repeatability | Opposed:100 microseconds
Convergent:160 microseconds
|
| Indicators | 2 LED Indicators:Green and Yellow
Green ON steady:power to sensor is ON
Green flashing:output overload
Yellow ON steady:light is sensed
Yellow flashing:marginal excess gain (1-1.5x) in light condition
|
| Construction | Opposed:Black ABS housing with clear MABS lens
Convergent:Black ABS housing with clear acrylic lens
|
| Environmental Rating | IEC IP67; NEMA 6
|
| Connections | 2 m or 9 m attached PVC cable, or 150 mm pigtail with threaded 3-pin Pico-style quick-disconnect fitting. QD cables are ordered separately.
|
| Operating Conditions | Temperature:-20° to +55° C
Relative humidity:80% @ 50° C (non-condensing)
|
| Vibration and Mechanical Shock | Vibration:All models meet IEC 60068-2-6, IEC 60947-5-2, UL491 Section 40, MIL-STD-202F Method 201A; 10 to 60 Hz, 0.5 mm peak to peak
Shock:All models meet IEC 60068-2-27, IEC 60947-5-2; 30g peak acceleration, 11 millisecond pulse duration, half-sine wave pulse shape
|
| Application Notes | M2 stainless-steel mounting hardware is included with each sensor. Optional mounting brackets are available.
|