| Supply Voltage and Current | 15 to 30V dc (10% max. ripple) @ 70 mA max. (exclusive of load) |
|---|---|
| Sensing Range | Q50AVI and Q50AVU models:50 to 150 mm Q50AI and Q50AU models:50 to 200 mm Q50BVI and Q50BVU models:100 to 300 mm Q50BI, and Q50BU models:100 to 400 mm |
| Sensing Beam | Wavelength: Q50AVI, Q50AVU, Q50BVI and Q50BVU models:685 nm typical
Q50AI, Q50AU, Q50BI and Q50BU models:880 nm typical
Beam Size:20 mm dia. max. |
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Output Configuration | 4-20 mA current sourcing models:1 k ohm max. load @ 24V dc; max. load = [(Vcc-4.5)/0.02] ohms 0-10V voltage sourcing models:15 mA max. |
| Output Protection Circuitry | Protected against short circuit conditions |
| Output Response Time | Fast: Average interval:4 milliseconds
Update rate:1 millisecond
-3 dB frequency response:112 Hz
Slow:Average interval:64 milliseconds
Update rate:4 milliseconds
-3 dB frequency response:7 Hz
|
| Delay at Power-up | 2 seconds |
| Resolution | Q50B models: Target distance:200 mm
Slow response:1 mm max.
Fast response:4 mm max.
Q50A models:Target distance:100 mm
Slow response:0.5 mm max.
Fast response:2 mm max.
|
| Linearity | Q50B models:±3 mm Q50A models:±1.5 mm |
| Temperature Drift | Q50B models: From 0° to 50° C :-0.25 mm/° C
From -10° to 55° C:-0.35 mm/° C
Q50A models:From 0° to 50° C:0.08 mm/° C
From -10° to 55° C:0.11 mm/° C
|
| Remote TEACH and Speed Input Impedance | 15 k ohms |
| Remote TEACH Input | To TEACH:connect gray wire to +5 to 30V dc To disable:connect gray wire to 0 to +2V dc (or open connection) |
| Adjustments | Fast speed:connect black wire to +5 to 30V dc Slow speed:connect black wire to 0 to +2V dc (or open connection) |
| Indicators | Range LED indicator:Green/Red Green ON steady:target is within sensing range
Red ON steady:target is outside sensing range
Green flashing:outputs are overloaded
OFF:sensor power OFF
TEACH/Output LED indicator:Yellow/RedYellow (window limits):target is within taught window limits
Yellow (fixed field):target is closer than cutoff limit
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
|
| Minimum Taught Window | Q50B models: Target distance @ 300 mm:50 mm window
Target distance @ 125 mm:10 mm window
Q50AVI and Q50AVU models:Target distance @ 50 mm:5 mm window
Target distance @ 75 mm:10 mm window
Target distance @ 100 mm:15 mm window
Target distance @ 125 mm:20 mm window
Q50AI and Q50AU models:Target distance @ 50 mm:5 mm window
Target distance @ 75 mm:10 mm window
Target distance @ 100 mm:15 mm window
Target distance @ 125 mm:20 mm window
Target distance @ 150 mm:25 mm window
Target distance @ 175 mm:35 mm window
Target distance @ 200 mm:50 mm window
|
| Ambient Light Immunity | less than 10,000 lux. |
| Construction | Housing:molded ABS/Polycarbonate Window lens:acrylic |
| Environmental Rating | IEC IP67; NEMA 6P |
| Connections | 5-conductor 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-10° to +55° C Relative humidity:90% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |