| Supply Voltage at the Device | 24V dc ±15% (SELV), ±10% max. ripple (The external voltage supply must be capable of buffering brief mains interruptions of 20 milliseconds, as specified in IEC/EN 60204-1). |
|---|---|
| Supply Current | Emitter:100 mA max. Receiver:275 mA max., exclusive of OSSD1 and OSSD2 loads (up to an additional 0.5 A each) |
| Resolution† and Operating Range (†No blanking enabled) | 14 mm resolution models:0.1 to 6 m 30 mm resolution models:0.1 to 18 m Range decreases with use of mirrors and/or lens shields: Lens shields:approximatel 10% of range per shield
Glass surface mirrors:approximately 8% less range per mirror
|
| Response Time | Dependent on number of sensing beams
10 beams:9 milliseconds 20 beams:11 milliseconds 30 beams:13 milliseconds 40 beams:15 milliseconds 50 beams:17 milliseconds 60 beams:19 milliseconds 70 beams:21 milliseconds 80 beams:23 milliseconds 90 beams:25 milliseconds 100 beams:27 milliseconds 110 beams:30 milliseconds 120 beams:32 milliseconds 140 beams:36 milliseconds 160 beams:40 milliseconds 180 beams:43 milliseconds 200 beams:48 milliseconds 220 beams:52 milliseconds 240 beams:56 milliseconds |
| CSSI Response Time (SLSC.. cascade models only) | Response time for a cascade receiver due to opening contacts at the cascade interface (CSSI) is 40 milliseconds max. (contacts must open for 60 milliseconds min.). |
| Remote Test Input (Optional - available only SLSE..-..Q5 emitters) | Test Mode is activated either by applying a low signal (less than 3V dc) to emitter TEST #1 terminal for a minimum of 50 milliseconds, or by opening a switch connected between TEST #1 and TEST #2 for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked condition. A high signal at TEST #1 deactivates Test Mode. (See p/n 112852 for more information.)
High signal:10 to 30V dc
Low signal:0 to 3V dc
Input current:35 mA inrush, 10 mA max.
|
| Wavelength of Emitter Elements | Infrared LEDs, 950 nm at peak emission |
| EDM Input | +24V dc signals from external device contacts can be monitored (one-channel, two-channel or no monitoring) using EDM1 and EDM2 terminals in the receiver. Monitored devices must respond within 200 milliseconds of an output change.
High signal:10 to 30V dc @ 30 mA typical
Low signal:0 to 3V dc
Dropout time:200 milliseconds max.
|
| Reset Input | The Reset input must be high for 0.25 to 2 seconds and then low to reset the receiver.
High signal:10 to 30V dc @ 30 mA typical
Low signal:0 to 3V dc
Closed switch time:0 .25 to 2 seconds
|
| Safety Outputs | Two redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs. (Use optional interface modules for ac or larger dc loads.) Capable of the Banner “Safety Handshake”. ON-state voltage:greater than or equal to Vin-1.5V dc
OFF-state voltage:1.2V dc max. (0-1.2V dc)
Max. load capacitance:1.0 µF
Max. load inductance:10 H
Leakage current:0.50 mA max.
Cable resistance:10 ohms max.
OSSD test pulse width:100 to 300 microseconds
OSSD test pulse period:5 to 27 milliseconds (varies with number of beams)
Switching current:0-0.5 A
|
| Controls and Adjustments | Emitter: Scan Code selection:2-position switch (code 1 or 2). Factory default position is code 1.
Receiver:Scan Code selection:2-position switch (code 1 or 2). Factory default position is code 1.
Trip/Latch Output selection:Redundant switches. Factory default position is T (Trip)
EDM/MPCE Monitor selection:2-position switch selects between 1- or 2-channel monitoring. Factory default position is 2.
Reduced Resolution (2-beam Floating Blanking):Redundant switches to enable. Factory default is OFF.
|
| Short Circuit Protection | All inputs and outputs are protected from short circuits to +24V dc or dc common |
| Electrical Safety Class (IEC 61140: 1997) | III |
| Safety Rating | Type 4 per IEC 61496-1, -2; Category 4 per ISO 13849-1 (EN 954-1) |
| Ambient Light Immunity | Greater than 10,000 lux @ 5° angle of incidence |
| Effective Aperture Angle (EAA) | Meets Type 4 requirements per IEC 61496-2, ±2.5° @ 3 m |
| Enclosure | Material:Extruded aluminum housing with yellow polyester powder finish standard and well-sealed, rugged die-cast zinc end caps, acrylic lens cover, copolyester access cover. End caps on silver models are also nickel-plated. ESD-safe models have static-dissipative acrylic lens cover. |
| Environmental Rating | IEC IP65 |
| Status Indicators | Emitter: One bicolor (Red/Green) status indicator:indicates operating mode, lockout or power OFF condition
7-segment Diagnostic indicator:indicates proper operation, scan code or error code
Receiver:Yellow Reset indicator:indicates whether system is ready for operation or requires a reset
Bicolor (Red/Green) Status indicator:indicates general system and output status
Bicolor (Red/Green) Zone Status indicators:indicates condition (clear or blocked beam) of a defined group of beams
7-segment Diagnostic indicator:indicates proper operation, scan code or error code, total number of blocked beams
|
| Mounting Hardware | Emitter and receiver each are supplied with a pair of swivel end-mounting brackets. Models longer than 900 mm also include a swivel center-mount bracket. Mounting brackets are 8-gauge cold-rolled steel, black zinc finish. |
| Shock and Vibration | EZ-SCREEN components have passed vibration and shock tests according to IEC 61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm single amplitude (0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles). |
| Operating Conditions | Temperature:0° to +55° C Relative humidity:95% (non-condensing) |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN System: 14 mm, 30 mm Models | 112852 | 7.2MB | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN with Aux Output Option Supplement | 141244 | 434K | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN Systems: 14 mm, 30 mm Models (Semi-Annual Procedure) |
113362 | 75K | Download Email |
| 2. | EZ-SCREEN Systems: Stand-Alone 14 mm, 30 mm Models (Daily Procedure) |
113361 | 221K | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN Flyer - Chinese (Traditional) |
TWEZS201103 | 2.2MB | Download Email |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »Browse by model family or type in your model number to find STEP, IGS, DXF, or PDF files for your project.
Find them now »Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code