| Emitter/Receiver Range | 400 mm to 4 m (16 in. to 13 ft.) |
|---|---|
| Field of View | Nominally ±3° |
| Beam Spacing | 5 mm (0.2 in) |
| Light Source | Infrared LED |
| Minimum Object Detection Size | Straight Scan, Low-Contrast: 5 mm (0.2 in) Straight Scan, High-Excess-Gain: 10 mm (0.4 in) See Figure 2-5 for other scan mode values; size is tested using a rod. |
| Sensor Positional Resolution | Straight Scan: 5 mm (0.2 in) Double-Edge Scan: 2.5 mm (0.1 in) Single-Edge Scan: 2.5 mm (0.1 in) |
| Supply Voltage (Limit Values) | Emitter: 12 to 30V dc Receiver Models: 18 to 30V dc |
| Supply Power Requirements | Emitter/Receiver Pair (Exclusive of Discrete Load): Less than 9 watts Power-up delay: 2 seconds |
| Teach Input (Receiver Gray Wire) | Low: 0 to 2 volts High: 6 to 30 volts or open (input impedance 22 K ohms) |
| Two Discrete Outputs | Protected against false pulse on power-up and continuous overload or short circuit. Discrete Output 1 (SIO Mode) Type: Solid-State Push-Pull Rating: 100 mA maximum (sourcing or sinking) ON-State Saturation Voltage: less than 3V @ 100 mA (sourcing or sinking) Discrete Output 2 Type: Solid-State NPN or PNP (current sinking or sourcing) Rating: 100 mA maximum OFF-State Leakage Current: NPN: less than 200 uA @ 30V dc; PNP: less than 10 uA @ 30V dc ON-State Saturation Voltage: NPN: less than 1.6V @ 100 mA; PNP: less than 2.0V @ 100 mA |
| Two Analog Outputs | Voltage Sourcing: 0 to 10V (maximum current load of 5 mA) |
| IO-Link Communication Interface | Baud Rate: 230, 400 bps Parity: Even Stop Bit: 1 Process Data Width: 16 bits |
| Scan Time | Scan times depend on scan mode and sensor length. Straight scan times range from 2.8 to 26.5 ms. See Figure 2-8 for all combinations. |
| System Configuration (Receiver Interface) | 6-position DIP switch: Used to set scanning type, measurement modes, analog slope, and discrete output 2 function (see Configuration DIP Switch on page 27 of IO-Link Instruction Manual) Push Buttons: Two momentary push buttons for alignment and gain level selection |
| System Configuration (IO-Link Interface) | Supplied IODD files provide all configuration options of receiver interface, plus additional functionality; see Overview on page 5 of Instruction Manual and IODD (IO-Link Device Description) on page 33 |
| Status Indicators | See Status Indicators on page 7 of Instruction Manual |
| Connections | Communication Interface: The receiver uses a cable splitter that converts the 8-pin connector to a compatible M12 IO-Link connector; see Cordsets and Connections on page 17 of Instruction Manual. Other Sensor connections: 8-conductor quick-disconnect cables (one each for emitter and receiver), ordered separately; see Cordsets and Connections on page 17 for available lengths (may not exceed 75 meters long), PVC-jacketed cables measure 5.8 mm diameter, have shield wire; 22-gauge conductors. |
| Construction | Aluminum housing with clear-anodized finish Acrylic lens cover |
| Environmental Rating | IEC IP65 |
| Operating Conditions | Temperature: -40° to +70° C (-40° to +158° F) Maximum relative humidity: 95% at 50° C (non-condensing) |
| Certifications | CE; IO-Link |
Helpful application information, new product updates, answers to frequently asked questions, and more.