cart

Configurable Safety Controller: SC22 Series

SC22 Safety Controller

SC22 Safety Controller
SC22-3_Controller_exploded

Non-safety monitoring of the Safety Controller I/O via Ethernet network communications, including Modbus/TCP, Ethernet I/P and PCCC.

  • Uses an RJ45 Ethernet connector and standard or crossover-style cordsets to communicate via Ethernet communications protocols
  • 32 configurable virtual status outputs with "Auto Configuration" option
  • Network access to the Fault Log and System/Network parameters
  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1
  • 3 pairs of solid-state safety outputs rated at 0.5A each (24V dc) with selectable one- or two-channel external device monitoring and ON-delay or OFF-delay
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions
  • Live Display and a Fault Log provide real-time system and fault history identification
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1

    Technical Literature

    Date
    Type
    Size
    SC22-3, SC22-3E Safety Controller
    29 Oct 2015
    Product Manual
    6.1MB
    SC22-3, SC22-3E Safety Controller Configuration Tutorial
    27 Sep 2010
    Product Manual
    1MB
    SC22-3 Safety Controller Quick Start Guide
    9 Oct 2008
    Installation Guide
    2.7MB
    Date
    Type
    Size
    SC22-3 Safety Controller Instruction Manual - UK English
    04/15/09
    Product Manual
    12.2MB
    Date
    Type
    Size
    SC22-3 Safety Controller Instruction Manual - French
    06/18/09
    Product Manual
    10MB
    Date
    Type
    Size
    SC22-3 Safety Controller Instruction Manual - German
    07/11/08
    Product Manual
    10MB
    Date
    Type
    Size
    SC22-3 and SC22-3E Safety Controller - Japanese
    07/20/10
    Product Manual
    4.5MB

    Software

    Date
    Type
    Size
    Banner Safety Controller PC Interface v3.0
    10 Dec 2010
    Software
    66.1MB

    Product Data Files

    Date
    Type
    Size
    SC22 EDS File (June 8, 2015)
    8 Jan 2016
    EDS Files
    2.7MB

    Marketing Literature

    Date
    Type
    Size
    Simplifying Safety Feature Management
    11 Jan 2013
    Other
    714K
    SC22-3/-3E Safety Controller Brochure
    12 Oct 2012
    Product Brochure
    4MB
    Simplifying Safety Feature Management [Success Story]
    Simplifying Safety Feature Management [Success Story]

    Algus Packaging Inc. is a leader in the heat seal and thermoform packaging industry. They design, develop and manufacture high-performance sealing machines, thermoformed packaging and offer full service contract packaging. The machinery and services offered by Algus provide their customers with the ability to change and grow as business needs dictate, now and in the future.

    Read More
    Product Selection
    Loading...

    Narrow Results

    clear all filters

    +- Terminal Type

    • (4)
    • (2)
    • (4)

    +- Safe Output Type

    • (4)
    • (6)

    +- EtherNet/IP

    • (5)
    1. SC22-3-S

      logo with r symbol

      Safety Controller: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total)
      Kit includes: Removable screw terminals;
      Removable external memory card

    2. SC22-3E-S

      logo with r symbol

      Safety Controller Ethernet: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total); 32 Virtual Status Outputs
      Kit includes: Removable screw terminals;
      Removable external memory card

    3. SC-SC22-3

      logo with r symbol

      Safety Controller: 22 Inputs; 3 Safety Outputs (0.75 amp each);
      10 Status Outputs (1 amp total)
      Kit includes: Replacement SC22-3 only (no terminals or XM card)

    4. SC-SC22-3E

      logo with r symbol

      Safety Controller w/Ethernet: 22 Inputs; 3 Safety Outputs (0.5 A each)
      10 Status Outputs (1 amp total)
      Kit includes: Replacement SC22-3E only
      (no terminals or XM Card)

    5. SC22-3-C

      logo with r symbol

      Safety Controller: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total)
      Kit includes: Removable cage-clamp terminals;
      Removable external memory card

    6. SC22-3-CU1

      logo with r symbol

      Safety Controller: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total)
      Kit includes: Removable cage-clamp terminals;
      Removable external memory card; USB A-B cable; Remote programming tool

    7. SC22-3-SU1

      logo with r symbol

      Safety Controller: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total)
      Kit includes: Removable screw terminals;
      Removable external memory card; USB A-B cable; Remote programming tool

    8. SC22-3E-C

      logo with r symbol

      Safety Controller Ethernet: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total); 32 Virtual Status Outputs
      Kit includes: Removable cage-clamp terminals;
      Removable external memory card

    9. SC22-3E-CU1

      logo with r symbol

      Safety Controller Ethernet: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total); 32 Virtual Status Outputs
      Kit includes: Removable cage-clamp terminals;
      Removable external memory card; USB A-B cable; Remote programming tool

    10. SC22-3E-SU1

      logo with r symbol

      Safety Controller Ethernet: 22 Inputs; 3 Safety Outputs (0.75 A each)
      10 Status Outputs (1 amp total); 32 Virtual Status Outputs
      Kit includes: Removable screw terminals;
      Removable external memory card; USB A-B cable; Remote programming tool