cart

Q50 Series

LED Measurement Sensor

Q50BVI

 

  • Combines laser-like performance with LED safety and economy
  • Provides an appealing alternative to lasers for many applications, including dry-bulk level measurement, package filling, roll-diameter measurement, loop control and dimensional measurement
  • Available in discrete or analog models
  • Includes visible red models with 50 to 300 mm range and infrared models with 50 to 400 mm range
  • Features push-button TEACH-mode programming for custom sensing windows
  • Offers remote programming for added security and convenience
  • Allows choice of 4 or 64 millisecond output response speed
  • Provides sensor linearity less than 1 percent of full scale

       

Technical Literature

Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs (Long Range)
27 Oct 2003
Datasheet
654K
L-GAGE Q50 Series, Analog Output (Long Range)
27 Oct 2003
Datasheet
643K
L-GAGE Q50 Series, Discrete Outputs (Short Range)
27 Oct 2003
Datasheet
309K
L-GAGE Q50 Series, Analog Output (Short Range)
27 Oct 2003
Datasheet
299K
Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs, Long Range - Chinese (Simplified)
10/27/03
Datasheet
916K
L-GAGE Q50 Series, Analog Output, Long Range - Chinese (Simplified)
10/27/03
Datasheet
894K
Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs - Dutch
09/22/04
Installation Guide
172K
L-GAGE Q50 Series, Analog Output - Dutch
09/22/04
Installation Guide
178K
Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs - UK English
10/27/03
Datasheet
162K
L-GAGE Q50 Series, Analog Output - UK English
10/27/03
Datasheet
150K
Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs - French
09/24/04
Installation Guide
164K
L-GAGE Q50 Series, Analog Output - French
09/24/04
Installation Guide
181K
L-GAGE Q50 Series, Discrete Outputs - Long Range - French
09/24/04
Datasheet
218K
L-GAGE Q50 Series, Discrete Outputs - Short Range - French
09/24/04
Datasheet
247K
L-GAGE Q50 Series, Analog Output - Short Range - French
09/24/04
Datasheet
241K
L-GAGE Q50 Series, Analog Output - Long Range - French
09/24/04
Datasheet
241K
Date
Type
Size
L-GAGE Q50 Series, Analog Output - German
07/20/04
Installation Guide
533K
L-GAGE Q50 Series, Discrete Outputs - German
07/20/04
Installation Guide
540K
L-GAGE Q50 Series, Discrete Ouputs - Long Range - German
07/19/04
Datasheet
219K
L-GAGE Q50 Series, Analog Output - Short Range - German
07/19/04
Datasheet
240K
L-GAGE Q50 Series, Discrete Outputs - Short Range - German
07/19/04
Datasheet
245K
L-GAGE Q50 Series, Analog Output - Long Range - German
07/19/04
Datasheet
212K
Date
Type
Size
L-GAGE Q50 Series, Discrete Outputs - Italian
07/20/04
Installation Guide
163K
L-GAGE Q50 Series, Analog Output - Italian
07/20/04
Installation Guide
179K
L-GAGE Q50 Series, Discrete Outputs - Long-Range - Italian
07/19/04
Datasheet
217K
L-GAGE Q50 Series, Discrete Outputs - Short-Range - Italian
07/19/04
Installation Guide
244K
L-GAGE Q50 Series, Analog Output - Short-Range - Italian
07/19/04
Datasheet
239K
L-GAGE Q50 Series, Analog Output - Long-Range - Italian
07/19/04
Datasheet
211K
Date
Type
Size
L-GAGE Q50 Series - Japanese
04/20/11
Datasheet
799K
L-GAGE Q50 Series, Analog Outputs - Japanese
10/27/03
Datasheet
303K
Date
Type
Size
L-GAGE Q50 Series, Analog Outputs (Long Range) - Portuguese
10/27/03
Datasheet
657K
L-GAGE Q50 Series, Analog Output (Short Range) - Portuguese
10/27/03
Datasheet
657K
L-GAGE Q50 Series, Discrete Outputs (Short Range) - Portuguese
10/27/03
Datasheet
663K
L-GAGE Q50 Series, Discrete Outputs (Long Range) - Portuguese
10/27/03
Datasheet
665K
Date
Type
Size
L-GAGE Q50 Series, Discrete Output - Spanish
10/27/03
Datasheet
230K
L-GAGE Q50 Series, Analog Output  - Spanish
10/27/03
Datasheet
221K

Software

Date
Type
Size
Banner Sensors Graphical User Interface (GUI) Version 3.0
18 Jan 2017
Software
286.7MB

Marketing Literature

Date
Type
Size
Q50 sensor improves production  for tortilla manufacturer
1 Oct 2012
Other
595K
Measuring the Height of Baked Bread [Success Story]
Measuring the Height of Baked Bread [Success Story]

The bakery’s multi-staged baking process begins with mixing, kneading and fermentation and completes with proofing, baking and cooling. At each stage, experienced bakers perform quality checks for appearance, texture, size and weight. Loaves that do not meet the company’s standards are rejected for consumer sales. The company needed to build-in system capabilities to help them better manage their resources and maintain quality standards.

Read More
Monitoring Height of Tortilla Dough
Monitoring Height of Tortilla Dough

A US producer of authentic Mexican foods, such as tortillas and tostadas, strives to provide the best-tasting and freshest products for its consumers. In order to achieve this goal, consistency on the packaging line is key. The company was looking for a way to eliminate inconsistencies in their tortillas. Because they did not have a way to continuously monitor dough thickness on the production line, the dough nips often turned out either too high or too low, resulting in irregular tortilla sizes and weights. If a package of tortillas is under weight, it must be scrapped. In order to help eliminate waste and improve product consistency, the company worked with Banner to find a monitoring solution.

Read More
Dough Height Inspection
Dough Height Inspection

By using Banner’s L-GAGE Q50 (Q50) LED-based linear displacement laser sensors to detect dough height and depth prior to final proofing and baking, bakers can consistently maintain exact bread loaf dimensions.

Read More
Product Selection
Loading...

Narrow Results

clear all filters

+- Input/Output

  • (24)
  • (48)

+- Analog Resolution/Discrete Repeatability

  • (36)
  • (36)

+- Max Sensing Distance (mm)

  • (18)
  • (18)
  • (18)
  • (18)

+- Minimum Sensing Distance (mm)

  • (36)
  • (36)

+- Sensing Beam

  • (36)
  • (36)

+- Power Supply

  • (48)
  • (24)

+- Connection

  • (48)
  • (24)

+- QD Type/Cable Length

  • (24)
  • (24)
  • (24)
  1. Q50AVUQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  2. Q50BUQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  3. Q50BVIQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  4. Q50AI

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    2 m (6.5ft) Cable

  5. Q50AI W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  6. Q50AIQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  7. Q50AN

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    2 m (6.5ft) Cable

  8. Q50AN W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    9 m (30 ft) Cable

  9. Q50ANQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    Euro Quick-Disconnect

  10. Q50ANY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    2 m (6.5ft) Cable

  11. Q50ANY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (4 ms Response)
    9 m (30 ft) Cable

  12. Q50ANYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    Euro Quick-Disconnect

  13. Q50AP

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    2 m (6.5ft) Cable

  14. Q50AP W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    9 m (30 ft) Cable

  15. Q50APQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    Euro Quick-Disconnect

  16. Q50APY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    2 m (6.5ft) Cable

  17. Q50APY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    9 m (30 ft) Cable

  18. Q50APYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    Euro Quick-Disconnect

  19. Q50AU

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    2 m (6.5ft) Cable

  20. Q50AU W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  21. Q50AUQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 50-200 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  22. Q50AVI

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    2 m (6.5 ft) Cable

  23. Q50AVI W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  24. Q50AVIQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect With Shield

  25. Q50AVN

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary NPN (48 ms Response)
    2 m (6.5 ft) Cable

  26. Q50AVN W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary NPN (48 ms Response)
    9 m (30 ft) Cable

  27. Q50AVNQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary NPN (48 ms Response)
    Euro Quick-Disconnect With Shield

  28. Q50AVNY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Comlementary NPN (4 ms Response)
    2 m (6.5 ft) Cable

  29. Q50AVNY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Comlementary NPN (4 ms Response)
    9 m (30 ft) Cable

  30. Q50AVNYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Comlementary NPN (4 ms Response)
    Euro Quick-Disconnect With Shield

  31. Q50AVP

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (48 ms Response)
    2 m (6.5ft) Cable

  32. Q50AVP W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (48 ms Response)
    9 m (30 ft) Cable

  33. Q50AVPQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (48 ms Response)
    Euro Quick-Disconnect

  34. Q50AVPY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (4 ms Response)
    2 m (6.5ft) Cable

  35. Q50AVPY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (4 ms Response)
    9 m (30 ft) Cable

  36. Q50AVPYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 12 to 30 V
    Discrete Outputs: Complementary PNP (4 ms Response)
    Euro Quick-Disconnect

  37. Q50AVU

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    2 m (6.5ft) Cable

  38. Q50AVU W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 50-150 mm; Input: 15 to 30 V
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  39. Q50BI

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    2 m (6.5 ft) Cable

  40. Q50BI W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  41. Q50BIQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    Euro Quick-Disconnect

  42. Q50BN

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    2 m (6.5 ft) Cable

  43. Q50BN W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    9 m (30 ft) Cable

  44. Q50BNQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    Euro Quick-Disconnect

  45. Q50BNY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    2 m (6.5 ft) Cable

  46. Q50BNY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    9 m (30 ft) Cable

  47. Q50BNYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    Euro Quick-Disconnect

  48. Q50BP

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    2 m (6.5 ft) Cable

  49. Q50BP W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    9 m (30 ft) Cable

  50. Q50BPQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    Euro Quick-Disconnect

  51. Q50BPY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    2 m (6.5 ft) Cable

  52. Q50BPY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    9 m (30 ft) Cable

  53. Q50BPYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (4 ms Response)
    Euro Quick-Disconnect

  54. Q50BU

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    2 m (6.5 ft) Cable

  55. Q50BU W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Infrared LED Range: 100-400 mm; Input: 15 to 30 V dc
    Output: 0 to 10V; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  56. Q50BVI

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    2 m (6.5 ft) Cable

  57. Q50BVI W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 15 to 30 V dc
    Output: 4 to 20 mA; Response: 4 / 64 ms Selectable
    9 m (30 ft) Cable

  58. Q50BVN

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    2 m (6.5 ft) Cable

  59. Q50BVN W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    9 m (30 ft) Cable

  60. Q50BVNQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary NPN (48 ms Response)
    Euro Quick-Disconnect

  61. Q50BVNY

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    2 m (6.5 ft) Cable

  62. Q50BVNY W/30

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    9 m (30 ft) Cable

  63. Q50BVNYQ

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Comlementary NPN (4 ms Response)
    Euro Quick-Disconnect

  64. Q50BVP

    logo with r symbol

    Q50 Series: LED-based Triangulation Measurement
    Visible Red LED Range: 100-300 mm; Input: 12 to 30 V dc
    Discrete Outputs: Complementary PNP (48 ms Response)
    2 m (6.5 ft) Cable