PM Series - Wire Replacement

DX80 PM Gateway 900 MHz Image
DX80 PM Gateway 900 MHz Image
DX80 PM Gateway 2.4 GHz Image

An I/O Radio network that combines long range line-of-sight coverage with ease of deployment and use.

The PM Series provides a flexible network that easily sets up without software. Setting up a basic point-to-point network is as easy as pairing a cell phone to a headset. You can replace cables and extend the range of digital and analog signals with minimal effort. 

  • No software needed
  • Menu-driven LCD user interface
  • Choose from two I/O configurations
  • Select from multiple I/O maps
  • One gateway is preconfigured to support up to two (PM2) or six (PM8) nodes
  • IP67 rated housing for demanding environments

Technical Literature

Date
Type
Size
Sure Cross Performance DX80 Wireless I/O Networks Instruction Manual
12/07/16
Product Manual
10.8MB
Quick Start Guide - PM8 Gateway to PM8 Node
10/05/16
Quick Start Guide
230K
Performance PM8 Kits
07/01/16
Datasheet
174K
Performance Node PM8 with I/O Mapping
07/01/16
Datasheet
255K
Performance Gateway PM8 with I/O Mapping
07/01/16
Datasheet
403K
Performance Gateway PM2 with I/O Mapping
06/30/16
Datasheet
408K
Quick Start Guide - PM2 Gateway to PM2 Node
06/30/16
Quick Start Guide
222K
Sure Cross Performance PM2 Kits
06/30/16
Datasheet
194K
Performance Node PM2 with I/O Mapping
06/30/16
Datasheet
263K
Sure Cross Installation Guide (DX80, Performance, and MultiHop)
04/17/15
Other
848K
Sure Cross Antenna Basics
03/05/14
Product Manual
1.1MB
Extended Address Mode and Binding
02/19/14
Product Manual
144K
Power Solutions and Battery Life Calculations
02/19/14
Product Manual
361K
Sure Cross Sensor Connections Guide
01/29/14
Product Manual
95K
Conducting a Site Survey and Interpreting the Results
07/02/13
Product Manual
205K
Sure Cross Network Basics Reference Guide
12/05/11
Product Manual
1.3MB

Software

Date
Type
Size
Sure Cross User Configuration Tool (2nd Gen)
09/01/16
Software
2.3MB
Sure Cross User Configuration Tool (32-bit version)
12/18/13
Software
12.3MB
Sure Cross User Configuration Tool (64-bit version)
12/18/13
Software
13.5MB

Product Data Files

Date
Type
Size
Performance Gateway Pro EDS File (Sept. 16,2016)
09/16/16
EDS Files
1.1MB

Marketing Literature

Date
Type
Size
Wireless Vibration and Temperature Sensor
10/04/16
Product Brochure
808K
Simple Wire Replacement Brochure
03/03/16
Product Brochure
743K
Wireless HVAC Monitoring Flyer
03/03/16
Product Brochure
290K
Wireless Catalog - 1st Edition
02/15/16
Catalog
8.3MB
Wireless Control Panel Temp & HumidityFlyer
02/05/16
Product Brochure
274K
Wireless Promotional Flyer
06/18/15
Product Brochure
540K
Wireless Eyewash Shower Flyer
03/06/15
Product Brochure
148K
Wireless Brochure
Wireless Brochure
01/29/14
Product Brochure
2.3MB
SureCross PM Series Flyer
10/25/13
Product Brochure
189K
Sure Cross Wireless Security
12/13/11
Other
128K
Wireless Call for Parts
Wireless Call for Parts

With high-quality LED lights and multiple colors in one device, Banner's multi-segment audibleTL50, combined with the K50 Touch and PM8 wireless system result in efficient call for part processes. To begin, Banner’s K50 ergonomic touch buttons are installed in a supervisor station and numbered according to their corresponding PML8 Wireless Nodes, which are installed at individual workstations along with an audible tower light.

Read More
Call for Parts at a Furniture Manufacturer
Call for Parts at a Furniture Manufacturer

The customer needs a solution that can increase the forklift operator's response time by putting indicators on the forklift's dashboard and can also allow the forklift operator to acknowledge the request, which eliminates redundant part deliveries by multiple operators.

Read More
Streamlining Call for Parts or Service
Streamlining Call for Parts or Service

To improve efficiency, assemblers at work stations need a way to call for parts and service that doesn’t involve them leaving their work stations. Getting parts more quickly would improve production efficiency, and using a system of remote indicators would let the supervisors to see the status of each work station, allowing the supervisors to fix production problems quickly and to collect production metrics.

Read More
Remote Monitoring Calculates Machine Run Time
Remote Monitoring Calculates Machine Run Time

During normal operation, operators load a welding machine with the frame components to be welded. The customer needed accurate machine run time data to determine why production goals were not being met.

Read More
Controlling Pumps Using a Solar-Powered Repeater System
Controlling Pumps Using a Solar-Powered Repeater System

A Performance Mapping (PM2) Gateway and two PM2 Nodes (900 MHz, 1 W models), using the 1R mapping option, transmit the signal from the reservoir to the pump station. One of the Nodes was installed at the reservoir with the float switch as its input. A solar panel was used to power the float switch and the Node. The Gateway, also powered by a solar panel, was installed part way down the hill to act as a repeater and ensure the signal was strong between the reservoir and the pump station. The second Node was wired into the pump station’s PLC. When the signal from the float switch indicated the reservoir’s levels were low, the pump turned on.

Read More
Product Selection
Loading...

Narrow Results

clear all filters

+- Device Type

  • (8)
  • (4)
  • (10)

+- Housing Style

  • (3)
  • (10)
  • (5)

+- Input/Output

  • (10)
  • (12)

+- Modbus RTU

  • (12)

+- RS-485

  • (12)

+- Radio Frequency

  • (11)
  • (11)
  1. DX80G2M6S-PM2

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    2.4 GHz, IP67 /NEMA 6
    Inputs:Four selectable NPN/PNP discrete
    Two 0-20mA
    Outputs: Four PNP discrete; Two 0-20 mA

  2. DX80G2M6S-PM8

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    2.4 GHz, IP67 /NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  3. DX80G9M6S-PM2

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    900 MHz, IP67 /NEMA 6
    Inputs:Four selectable NPN/PNP discrete
    Two 0-20mA
    Outputs: Four PNP discrete; Two 0-20 mA

  4. DX80G9M6S-PM8

    logo with r symbol

    PM Series Gateway - LCD Selectable I/O Mapping
    900 MHz; IP67/NEMA 6
    Inputs: Six Selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  5. DX80K2M6-PM8

    logo with r symbol

    PM8 Series Kit
    Includes one gateway and one node
    pre-mapped and pre-bound
    2.4 GHz 100 mW
    LCD Selectable I/O Mapping
    IP67 / NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  6. DX80K9M6-PM2

    logo with r symbol

    PM2 Series Kit
    Includes one gateway and one node
    pre-mapped and pre-bound
    900 MHz 1 Watt / 250 mW
    LCD Selectable I/O Mapping
    IP67 / NEMA 6
    In: Four selectable NPN/PNP discrete; Two 0-20 mA

  7. DX80N2X6S-PM2

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    2.4 GHz, IP67 /NEMA 6
    Inputs:Four selectable NPN/PNP discrete
    Two 0-20 mA
    Outputs: Four PNP discrete; Two 0-20 mA

  8. DX80N2X6S-PM8

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    2.4 GHz, IP67 /NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  9. DX80N9X6S-PM2

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    900 MHz, IP67 /NEMA 6
    Inputs:Four selectable NPN/PNP discrete
    Two 0-20 mA
    Outputs: Four PNP discrete; Two 0-20 mA

  10. DX80N9X6S-PM8

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    900 MHz, IP67 /NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  11. DX80G2M6S-PM2C

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    2.4 GHz, IP20 /NEMA 1
    Inputs:Four selectable NPN/PNP discrete, two 0-20mA
    Outputs: Four PNP discrete, two 0-20mA
    External Terminals

  12. DX80G2M6S-PM8C

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    2.4 GHz, IP20 /NEMA 1
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete
    External Terminals

  13. DX80G9M6S-PM2C

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    900 MHz, IP20 /NEMA 1
    Inputs:Four selectable NPN/PNP discrete, two 0-20mA
    Outputs: Four PNP discrete, two 0-20mA
    External Terminals

  14. DX80G9M6S-PM8C

    logo with r symbol

    PM Series Gateway -LCD Selectable I/O Mapping
    900 MHz, IP20 /NEMA 1
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete
    External Terminals

  15. DX80K2M6-PM2

    logo with r symbol

    PM2 Series Kit
    Includes one gateway and one node
    pre-mapped and pre-bound
    2.4 GHz 100 mW
    LCD Selectable I/O Mapping
    IP67 / NEMA 6
    In: Four selectable NPN/PNP discrete; Two 0-20 mA

  16. DX80K9M6-PM8

    logo with r symbol

    PM8 Series Kit
    Includes one gateway and one node
    pre-mapped and pre-bound
    900 MHz 1Watt / 250 mW
    LCD Selectable I/O Mapping
    IP67 / NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  17. DX80N2X6S-PM2C

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    2.4 GHz, IP20 /NEMA 1
    Inputs:Four selectable NPN/PNP discrete, two 0-20mA
    Outputs: Four PNP discrete, two 0-20mA
    External Terminals

  18. DX80N2X6S-PM8C

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    2.4 GHz, IP20 /NEMA 1
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete
    External Terminals

  19. DX80N2X6S-PM8L

    logo with r symbol

    PM Series Node- Basic Model (No LCD)
    2.4 GHz, IP67 /NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete

  20. DX80N9X6S-PM2C

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    900 MHz, IP20 /NEMA 1
    Inputs:Four selectable NPN/PNP discrete, two 0-20mA
    Outputs: Four PNP discrete, two 0-20mA
    External Terminals

  21. DX80N9X6S-PM8C

    logo with r symbol

    PM Series Node- LCD for Diagnostics
    900 MHz, IP20 /NEMA 1
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete
    External Terminals

  22. DX80N9X6S-PM8L

    logo with r symbol

    PM Series Node- Basic Model (No LCD)
    900 MHz, IP67 /NEMA 6
    Inputs: Six selectable NPN/PNP discrete
    Outputs: Six PNP discrete